ae2 me controller max size. B:Channels=true. ae2 me controller max size

 
 B:Channels=trueae2 me controller max size Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee)

ぜひマスターしましょう. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. One side of the me controller. Layers alternate ME interfaces connected to the dense cable, so each ME interface has access to 3 (top/bottom) or 4 assemblers. ago. My brother and I completed (up until Avaritia because mindless grind) Enigmatica 2 Expert with just 3 ME Controller blocks, and we had pretty much every machine set up for auto-crafting, and made recipes for. It has its own energy units which will be created inside the machine itself. In that setup each interface was adjacent to at least 3 assemblers, which was the max a Crafting CPU with no co-processors could utilize. Read below for info and updates on the subject!Fantasy This page is about the ME Controller added by Applied Energistics 2. I believe TKH made a controller that gave him 22841 channels at his disposal. Depends on what you're running though. Top 1% Rank by size . Commonly used for Sub-Networks. Join. Thanks (?) to YoungOnionMC. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). P2P stands for Point to Point. The ME Controller was only really necessary for when there are channels. 6 P2P MLG Pro . The current AE2 developer has said that he does not want the storage system to be a power provider. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. A Network requires power, which can be provided by various blocks, and may require ME. Its theme is centered around the concept of converting matter into energy and vice versa, to store and transport your items and fluids instantaneously!Your Applied Energistics storage system will probably not work without a ME Controller. So you can have as many inserters (conduits) and belts and whatever items that you need to automate your factory. Each block has a placed or gap state, so 2 ^ 343 = 1. ) All Spatial Pylons must be in the outside bounding box. The ME Import Bus will scale its transfer speed based on how much it has been working, and Acceleration Cards will make that scaling (and possibly max speed) much faster. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. The Drawer Controller is a block added by Storage Drawers. Construct a basic AE network (tested with a single AE controller connected to a creative energy cell and an ME chest with a 64k storage cell in it) attach adapter to ME controller and computer; Place 2 diamond swords in. A "Sub-Network" is a separate ME Network that augments another network. Contents. Each face can provide up to 32 channels when connected with an ME Dense Covered Cable. Ah ok, so just a bigger set up I guess. Smart, covered, or normal ME cable = 8 channels carrying capacity. I was partly going for wanting it to look a bit diff anyhow. 1 AE2AO 8. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several controllers in the same network. One click will extract a single item. Follow the Feed The Beast Wiki on Discord or Mastodon! READ MORE. ME Cable can also be colored with dyes. The ME Controller's texture will change to display the stored energy level for network use. The basic overview idea is that you deposit items into a buffer inventory, then sort them to four (or more) different Inscribers (one for each Inscriber Plate variant), and then to a 5th Inscriber for final assembly, and finally back into the storage system. like it doesnt exist. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. 139. All controllers on a network must be connected pretty self explanatory. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). wireless. An updated guide on large ME controllers and P2P networking. Now your next recipe should be named item 1 + the next 8 components = named item 2. Screenshots. #4. It's basically like taking a storage cell and limiting it to only hold one or 2 or how ever many, really different items. It is used to interact with a group of drawers. Or just do the level emitter thing, or external automated crafters and pre. (ME interface, screens, autocrafters, anything) Each side of your ME Controller block has 32 available channels. With auto crafting accessible via a p2p connected to the yellow network. This mod is server side only. I'm not a big fan of watching 30 minute tutorial videos to get started in a mod, so here's some basics: The only things you absolutely need for an ME network are some kind of power source and an ME controller. (16x16 area) Describe the feature: +1 range from the controller. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). The mod includes a network-based storage sy. ME Controller · ME Power Relay. More posts you may like. The ME Wireless Access Point is a block added by the Applied Energistics 2 mod. Différents appareils peuvent être connectés au Réseau ME, tels que le ME Drive, pour le stockage. One Route to the controller: AE2 devices auto-connect. 12. More posts you may likeDrawer A. Get to know AE2 in a new way! - Download the Minecraft Mod AE2 Additional Opportunity by Domaman202 on Modrinth. If you max that out, that's 64 machines running on your 1 cable. It will use only one channel. The Wireless Booster is an item added by the Applied Energistics 2 mod. AE2 network is small, 20 64K drives, 20 ME interfaces and 20 molecular assemblers but no patterns (issue happens with just controller). You only need 1 cable at the top of the 8 drives in each “block”. Sort by:Possible Upgrades. ME Drives are a device in Applied Energistics 2 which allow users to store up to 10 ME Storage Cells as opposed to a single cell that can be placed in a ME Chest . I found an old bug report (5 years ago) about me multiblocks chunk loading, so I isolated the controllers. 12. Alternative, use a level controller pointing to the machine or an export bus/interface with a crafting card set to make the item you want. Feed The Beast Wiki. Void junk/non stackable items or store. The ME Controller has a maximum length of 7 blocks total B. The problem is as of now you can get 2304 channels in a 3x3 with all the centers punched out so it’s hard to beat that. What I don't like about AE2's CPU is you need 3 parts: the CPU, an ME interface, and a molecular. The ME Quantum Network Bridge device is a multiblock unit capable of connecting distant ME networks together. I then use an Ender IO power monitor to turn the reactor on and off. There are limits to the number of devices you can have in a system (I think 8 without a controller, and then it's limited to the connections to the controller), but, as far as I can tell, all the devices can be interchangable, you could have 8 ME drives as a system, you just wouldn't be able to actually DO. D:perTickNetworkBridge= the number of AE units required to power a Quantnum Network Bridge. I'm not sure what the problem is because the Dense cables that I'm using only list 2/8 channels used, nowhere near the channel limit. Easy solution, create a quantum bridge for each of your "corridors" and attach each to a dense cable coming off your controller, that'll give you 32 channels per corridor to play with. 1. When you create a P2P into a dense cable, you are converting 32 channels from 1 facing into 1 channel. 3 sides total of 24 channels instead of using 4 sides using 4-6 channels. 容量 :8,000AE. Each of these towers currently uses 28 channels - 22 interfaces and 6 Crafting CPUs. There can be one controller on a network at most. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. Storage size Small Big Minimal Machine automation Yes No Only highly required (better fed by automation system) Long. Most devices such as standard cables, and machines can only support up to 8 channels. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. 0 alpha that provides wireless connections. ago. MAX_Y, MAX_Z (initially -> 7) - maximum controller size; SCFD (initially -> false) - allows me to make storage cells invulnerable to destruction by fire or lava; External resources. AE2 cables do not have a distance restriction, they have a connected device restriction, called "channels". This Solution's Drawback is using 2 Channels, so you'll need two lines of Dense Cables to run 32 Modules. Ae2 and drawers are compatible. Right-clicking materials on a Drawer Controller will automatically deposit the materials. This structure can be built in any cuboid, or size as long as the following Criteria are met. 12. Just put one ME Storage Bus on the Drawer Controller. Lazy AE2の導入方法. 10 Type : Item Stackable : Yes (64) Printed Silicon is an item added by the Applied Energistics 2 mod. r/feedthebeast. 2 One route to the controller: 1. Different devices can be connected to the ME Network, such as an ME Drive, for the storage of items, or an ME Terminal, allowing for access to that storage. The only ME Controller. No idea what you're attempting but from the explanation I don't think it's possible. The controller is a multiblock structure that follows a few rules: It can be no bigger by 7x7x7; A controller block must not connect to more than 2 other controller blocks on the same axis, or else it will idle; There can only be 1 on the network, or both will idle. But depending on the choosen balance between less or more effort the actual amount max might vary between values like 32, 128, 512 or 1024. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. This afternoon i'm going to aim to make the most potential one using smart cable only to see what size a good automated crafting AE system can do with only smart cable (#Challenge). . Hilbert controller has 510, so you're looking at almost exactly 30% more faces. Today I gonna show you how to use the cables from Applied Energistics 2. Build a Storage Drawers system, connect the Drawer Controller to the ME system with a Storage Bus (this will allow the AE system to see everything in the Drawer System that is inside a 12x12 area). The tutorial showcases how to craft and use the. When used with a Spatial IO Port and Spatial Pylons, the 1283 Spatial Storage cell will hold a physical area with the dimensions of 128x128x128, or an internal volume of 2,097,152 blocks. Tunnels are 1 input to N outputs. So the system keeps flickering on and off, we have no current power issues, I thought it could have been not enough power in the system so I added 3 cells, it didn't fix it, I. You can support me and the channel! Read more here: have done videos. One of the most popular methods is hooking an import bus (with acceleration upgrades) to an ender chest from ender storage. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. The ME Terminal is an item added by the Applied Energistics 2 mod. Specialised cells for certain conditions also do not make much sense as the idea for AE2 is still to provide as few basic options as possible, while allowing the player to combine it to fit their needs. setInterfaceConfiguration ( [slot:number] [, database:address, entry:number [, size:number]]):boolean. Fourth - there should be a channel being used on your P2P "service" network for each connected P2P device (assuming none of them are pointing the wrong way) as the P2P service networks rarely include a ME controller this means they max out at 8 P2P tunnel devices - for between 4 and 7 tunnels depending on how they are linked. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). But most AE2 machines still need power. ---> which I have all 3 controller blocks connected. There is a limit to how many sides can touch another controller. Machines operate at max speed (resonant + the 3 speed upgrades). 64k disks would store a lot more per disk, but the index is 4x the size. An ME interface allows you to pump things into it. 000,- if you set it up with only 64k units (no co unit, no crafting monitor). If a controller remains red, one of the rules are broken and the controller is. While the ME Chest is a great way to get introduced to the concept of ME, to really take advantage you need to. 14. 1. The mod allows you to: - Remove channel restrictions; - Connect controllers via cable; - Expand or shrink maximum multiblock size from controllers; - Turn off power usage. So for example, if you have an ME Cable facing all six sides, you can have a maximum (assuming no one cross-connects) of 48 channels from a single ME Controller. But in Minecraft you need to. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. All others (max. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). . You really need to count channel usage right at the controller. I was very well versed with AE1 and often had huge networks with lots of crafting abilities. i would suggest using a RFTools crafter to do a passive autocraft to keep stock of each level of essence (using drawers or something) as opposed to. • 1 yr. The structure must be an ME network with a number of Spatial Pylons which define the target region. More posts you may likeDrawer A. The ME System is used for storing items without using up much physical space. It can be small or big, but only one per network. ・まとめ AE2のみでも、各種素材要求物の自動化や実質容量を劇的に増やすこともできる。単体導入や、MODPackに入っていた場合でも安心。 が、強いこだわりや複雑な施設による負荷を避けたいなら、アドオンの「AE2 Stuff」を同時に導入すると、面倒な自動設備を数ブロックに圧縮できるため. size unless you do something like the last pic. Configure the interface. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. e. They only produce 10 AE/t (5 EU/t or 20 RF. The controller can also transmit an unlimited number of channels through itself. You are correct. Make sure that none of the cables of the same colors attach to each other, use different colors for cables and do not attach fluix cables directly to the. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable. Top 1% Rank by size . No crafting recipe for the AE2 version only chisel. and click on the faces until the one facing the ME Controller turns orange. . The barrier to entry for AE2 is terrible. . Jan 25, 2015. 1. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. 24-0. wireless. so you can go Energy Acceptor (1 channel) -> Main network cable->quartz cable->transport cable. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. Examples of these are enderio, project red, etc. Has 8 channels to play with. That means using glass cables you can have 8 devices wired into each side of your ME controller block. I have an Empowerer from Actually Additions 2, but it seems to be fighting for bandwidth with my Molecular Assemblers. ME Controllers output 32 channels per block face, so one singular controller has 6 faces x 32 channels = 192 total channels. 2 In Conclusion . This configuration seems to allow me to have as much as 9408 channels and i know that i don't really need this many, but it's fun to reach the limits sometimes. a 3x10x10 would work, but a 1x10x10 would not). Manages a single auto crafting task from start to finsh, built of various crafting units. Do what you normally would to join 2 p2ps and see whether it works. As I continue to dabble I may add in checking on the status of the requested jobs and bound the looping to when all requested jobs per loop-pass have been completed. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. The maximum length of one axis of the multiblock is 7 blocks; An ME Controller can have 2 adjacent blocks in at most 1 axis; Rule #3 essentially means that, of the 3 axes (north/south, east/west, up/down), only one of those axes can have 2 controller blocks on both sides of any given controller and that the other axes may only have one. 適切に隣接させるとマルチブロックになる。. Feed The Beast Wiki. Channels are just a funny way to say bandwidth. The CPU must contain at least 1 storage component. Configuration file (ae2ao. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. Part of a multi-block structure, used to digitally store the blocks within a certain space determined with the use of the Spatial Pylon. 7. To configure a P2P Tunnel you must first attune the tunnel to carry what you want it to, then you need to configure the outputs to their input. The default range of a wireless signal is 16 blocks, which can be increased by 2 blocks with a Wireless Booster. MEチェスト1. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. 2. Since the release of AE2, I've only kept basic networks (crafting terminal, controller, me drive, interfaces connected to machines). Whenever you have more than 8 devices in a network, an ME Contr. With the standard 1 EU = 4 RF conversion. A 4k disk is 4x the size and cost of a 1k disk and the index is 4x bigger. Any machine that is to be connected to a network requires 1 channel. At its most. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. Notifications Fork 556; Star 1. When Ae2 blocks touch each other imagine there is an infinitely small cable connecting touching sides and that they behave like electrical wire. (The controller doesn't handle data. The dense cable is connected to the controller via p2p interface. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. I was running 64 channels (in p2p) through quantum bridges to each of 5 islands, and about 400 on the main AE island. 4-rv6-stable-7. To fix this people build it in a box shape with only the corners of the box, or if you're like me, a line. Maximum size of the ME Controller multiblock is now configurable. This a max amount of 314. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. 1 AE2 Channel Surfing for Newbies (A Reference Guide for the Rest Of Us!) 1. In a chunk based design, it's not possible to place the controller in the middle of the room. Make a doughnut shaped controller multiblock with 8 controllers. (4) some EnderIO item conduits. ControllerLimits (initially -> false) - allows you to install several controllers in the same network (in the false state, allows you to set an unlimited number of controllers);. It is the heart of ME Networks and is used to provide more channels to the network. Not too shabby. com, stoneblock version is 1. This type of network is known as an "ad-hoc" network. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. I've attached leadstone pipe directly to the unit, but it didn't make a connection. That's 32x32 channels (1,024) going through a single dense cable line. I just use a normal reactor with a huge capacitor bank to store power. Raspberry Flavoured, a 1. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). Aesthetically, the AE1 CPU was bigger, which made it look cooler as the centerpoint of a base IMO. Set the level controller to 1000 torches and point it at an export bus for torches with a crafting. (note i don't have AE2 installed, so imagine the glass is an assembler and the iron is the interface)Applied Energistics 2 (AE2) is a mod which allows players to have a truly powerful storage network for all their items, as well as the complete automation of nearly all repetitive systems in ones’ base. 2; AE2 Version: rv6. 12. ME Cable is added by Applied Energistics. The ME Controller allows 32 channels to be used per side. . I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). 20, AE2 offers an in-game guide. Join. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several. It allows items to be inserted into or extracted from the ME System it is connected to. items in storage drawers and connect the controller to the ME network with a storage bus. With 1. If you want more than 8 devices on your network, you must have a Controller. It serves like a base to processors added by the mod. • 22 days ago. I have a one-controller carrier network between a hollow 3x3 controller and my devices and I'm at 140 channels without breaking a sweat. (2) One chest. Featured versions See all [FORGE. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. The current power level is indicated by a coloured bar on the front of the block. None yet. You can get more by utilizing every side you have and that would make it worth it you also don’t need dense cables coming off each thing you can place p2ps directly on the controllers unless you are doing it for aesthetics. Yes i have a controller (its AE2 btw) I already have 3 cards per bus, that didnt work. total size 29x29x9. CurseForge is one of the biggest mod repositories in the world, serving communities like Minecraft, WoW, The Sims 4, and more. They are usually very limited in scope and rarely directly accessed by the player (mostly for automation). Any help appreciated. The ME Controller's texture will change to display the stored energy level for network use. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. This is okay when dealing with busses, interfaces, and molecular assemblers. If you’re having trouble executing the mod, try reading this article of ours that teaches mod implementation for Minecraft. Hello, want to know why the MB limit is 17x17x17? This a max amount of 314. [deleted] • 7 yr. This mod focuses on presenting. Join. 1. No, they're saying that you don't need a controller multiblock, which could be 2 controllers or 343 controllers. (6) some EnderIO energy conduits for the power supply (if you want to be compact - they can share the space with the item conduits)OMFG THXS I loved ae1 and was heart broken when ae1 didn't get updated to 1. As your base network grows larger and larger, you will need to have at least one ME controller to hook up more devices to the network (a single controller gives 196 channels, or up. You could have 32 Input P2P tunnels feed into one dense cable and then into one side of a Controller, and the output tunnels will be on the other side of the controller. However, a regular glass cable will only hold 8. Basically, what this means is that of the 3 axis of the block (Up/Down, East/West, North/South) only one of them may have. Exterior: 578 Tunnels giving 18496 channels. Join. More than enough channels. #2. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Since Minecraft 1. The ME crafting terminal from ae2 tutorial. Networks without an ME Controller are considered Ad-Hoc and can support up to 8 channels of device usage. You can tell this by watching the AE controller energy go above its max amount before resetting back to its max amount and repeating. Hey Guys. B. Basically, what this means is that of the 3 axis of the block (Up/Down, East/West, North/South) only one of them may have. ME Controller may refer to: ME Controller (Applied Energistics) ME Controller (Applied Energistics 2)Applied Energistics 2’s Channels. ago. It is the new and overhauled version of the original Applied Energistics mod. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. When taken by itself, the ME Controller does nothing. This article is about ME Controller from Applied Energistics 2 . I've added a new block to AE2 Stuff 0. ) and Energy Units (EU). I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. jar; Forge Version:14. " Such networks are limited to only 8 Channels. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. 前提MODとして LibNine ・ Applied Energistics 2 を導入する。. The Quantum Field Ring is a block added by Applied Energistics that is used in the creation of the ME Quantum Network Bridge. It is part of Applied Energistics 2, a mod to digitalize storage and automate machines. you want interfaces to be completely covert with assemblers for maximum efficency and speed interfaces/assemblers can only transfer up to 8 channels, so that would be your max. I just use a normal reactor with a huge capacitor bank to store power. When right clicked, the Controller's GUI will display the state of the controller, the total energy stored, the energy draw of the network, and the devices connected to the ME Controller in the center (Note. Here's something that uses. ME Controllers output 32 channels per side. 生産 :40AE/t. The ME Chest shows you the contents of the Cell as soon as its placed inside, and you can add and remove items from it as if it were a Chest, with the exception that the items are actually stored in the Storage cells, and not the ME Chest itself. Every machine in AE2 takes up 1 channel. Every machine in AE2 takes up 1 channel. Once it's in. Yes, those conversions are one-way (AE2 is not an open power converter). They're both visually appealing in their own ways to me. No branches or pull requests. After the move I. 並列処理機構を組むにあたって重要な部分になります。. Up to 64 Boosters may be inserted for a total range of 528 block radius and an energy cost of 4. I'm finding that when my ME network gets to a larger size (to the level of hundreds of connected interfaces/buses), it keeps freezing up. Controller Network - A network with a Controller. 2 ae2-uel-extended-v0. ItsOswin 5 yr. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. Unlike the ME Chest, the items that are stored inside the storage cells cannot be directly accessed; instead the drive must be connected to a ME Network which allows. The Energy Acceptor converts most mods energy form to AE to power the Network, although, using a Quartz Wrench a Player may choose the preferred power unit. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. If you want some kind of storage- which in. In a check board pattern like shown you get 30 interfaces so just one side of a controller. 12. • 4 yr. Manages a single auto crafting task from start to finsh, built of various crafting units. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. Each device takes one channel. . I think that the most efficient controller possible doesn't have any loops- that is, the controller blocks form a long, perhaps branching, chain. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is 7x7x7, and that you can only have 3 blocks in a row without an air gap. I just logged on and now its doing nothing at all :S really strange, i can access the system/items but its not processing anything and there are still ores and dusts in the system, also there. Used versions: Forge: 2810 AE2: stable 6, Rv6 MC: 1. The best, most elegant way to automate them is to brute force them with Steve's Factory Manager. Now, I've crafted a couple of CM and CM tunnels but the AE2 cables didn't connect with the side of the cube neither inside or outside. It has to be touching the drawer bank. i currently have 2 energy acceptors connected to the same glass cable, and the.