Barotrauma reactor controller. A Wreck is a sunken hull, usually a Submarine. Barotrauma reactor controller

 
A Wreck is a sunken hull, usually a SubmarineBarotrauma reactor controller  If the turbine limit is too low, the reactor cannot use it's energy to drive the turbine and will overheat

Together with the added incentives for manual operation, this should make automatic reactor control still perfectly viable but no longer the objectively best way to run a reactor. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. Supplement your player count with bots as needed in either singleplayer or multiplayer game modes. Otherwise I reckon it's the most efficient. When the components are correctly configured the sliders will bounce between 0 and 100. You can alter the expression of the REGEX component [1-x] to be as high as 9. It's supposed to allow perfect efficiency. I usually just send a wire from the Reactor_Power_Out to a NOT component signal in and wire the emergency lights to the NOT component signal out. 01 * Reactor's max output) Fission rate = (Turbine output * 75) / fuel_out The components should be: 1) Memory for "0. There are some other benefits to using multiple rods, mainly that changing rods is less frequent and less movement of the needle is needed for fission rate. Banäne Nov 20, 2021 @ 5:01am. There is nothing we can do. Barotrauma Workshop. g. Members Online • Electronic-Lynx-9771 . SUBSCRIBE: me on discord: up to date on Twitter: I show you how. She was spoiled by the auto-reactor being able to flawlessly handle the reactor. Thank you in advance. Last edited by Buggy Boy; Jul 28. Press E with cursor on it (and a !screwdriver,!wire in hand), a menu will open 4. 2*. Barotrauma. You connect smoke detector output to a relay with 'signal 1' and 'set state' meaning if detector sends 0 (meaning no smoke) it shuts down whole relay and any signal is blocked until detector sends a 1. Barotrauma. The problem with Azimuth is it only have one super capacitor. You can build your own submarines and monsters with in-game editors and share your creations with other players. Repair reactor. Rhapsody Apr 10 @ 7:39am. In this guide we are going to look at a 5 component automatic reactor controller in Barotrauma, specifically on how to physically upgrade your submarine's re. however, if the reactor is off, all power is supplied from the outpost. This variant of the 2-component reactor controller automatically stops power production when docked!Keep in mind, if the thing you're docking with doesn't su. is the most basic form of power spike buffering. I'd recommended places two fuel rods. When repairs finished we scouted outside sub for dropped things and only found the upper torso of the mechanic that. Avoid Herja if you dont know how to wire automated reactor controller because this ship have no battery and has poor draining. Few days ago I got saw a post about Battery Buffer circuit that was made in anticipation of the nerfs to Reactor Controller Circuit, even though the nerfs were small enough that minor adjustments to it could fix, I still had an idea in my head, what's about combining those two? Imagine a RCC that works in tandem. But I decided I wanted to go further so it could be used throughout the game without being. It kinda needs something better than default reactor controller to handle voltages though. Play with up to 16 players on board a submarine. They are faster, will get more power from one rod and keep temperature to required minimum. The controller can hand four rods of any kind without overheating or providing over voltage. In this guide i will help you create the latest Barotrauma update compatible reactor controller, It is fuel efficient, hands free and meltdown avoiding. 2 Turbine Output 2. First, power on the reactor and turn off automatic control. Description. But so many patches and updates are moving more towards a normalized experience. If the control panel on the front of it is blue, you're golden! A blue control panel means that the reactor is at 100% health. Did u try turning off and on? the_mr_pickles • 3 yr. (and I think it wastes fuel as well but I'm not 100% on how the reactor works) if power is less than load things simply. This outputs -100 to 100 (adjusted by the neutral ballast value). SUBSCRIBE: me on discord: up to date on Twitter: I show you how. Reactor wiring trick Question Hey everybody. : r/Barotrauma. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumExample: reactor has 2000 max output, submarine somehow reaches 4000 load, which causes the controller to calculate turbine value of 200 and set the fission rate based on that 200, but since the turbine can't be set higher than 100 now the fission rate is 2x higher than it should be which can result in a reactor meltdown. I suggest using this graphite schem. I would suggest a greater than component in the temp control, that seems like what is happening. Once I got past the power issues, I learned to love the Winterhalter. This makes it the most heavily armed gunship in the seas of Europa. >Uncontrolled mining AI immediately removes suit in high pressure area. >Loads into reactor to use first cause Rad hazard. My mate's computer crashes. This was installed on the Kestral, the second value showed at 4999 (I give the mouse a good wiggle) is the ships maximum power potential, determined by winding the turbine fully while manually balancing heat. Take 1% of that and save it to a Memory component (ex. When held, it shows the interface of the controlled Nuclear Reactor, including the conditions of its Fuel Rods. The in game thing will be overwritten by the signals from the circuit, but this it is not as stable or precise as the circuit itself and can cause. If the reactor gets to 0% durability, it explodes - no questions asked. Everything you need to know about Reactors in BaroTraumaHope you guys enjoy! Don't forget to like and subscribe if you wanna see more!Discord: Barotrauma Extended, the reactor system has been entirely revamped. You must carefully manage the reactor's Fission Rate to manage the heat from the extra rods. I expanded upon Ignis' DIY Reactor Controllers, and added 4 new reactors. Together with the added incentives for manual operation, this should make automatic reactor control still perfectly viable but no longer the objectively best way to run a reactor. Hoist the sails! This update marks the last big content update before Barotrauma 1. Easy auto shutdown system setup. Best way to deal with power spikes without sub editor is:Making automated reactor controll from components. Összes Témák Képernyőmentések Alkotások Közvetítések Videók Műhely Hírek Útmutatók Értékelések. This is useful if you find your reactor needs to be hotter to better power your. Pretty cool. AI seems to ignore enemies that have no movement control. [bk]schorote Jan 3, 2020 @ 12:25pm. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. I had no idea that reactors had shielding to prevent radiation emission. So if you add a second rod it would be: (. 13. Herja by far, Typhon is currently THE most buggy and outdated ship in the whole vanilla roster. I suggest you leave “Automatic Control” off, and let it do its job. The new update adds a large delay to signals going into the reactor so now the Regex-GreaterThan controller will set the reactor to the output you needed about half a minute ago instead of your current need. 0 (barring any unexpected delays), so now is a fitting time to say thank you once. false output should be zero. Before the update, all methods of automated reactor control seemed to work fine. I’ve been doing a little research and I see automatic reactor controls have been nerfed. . here are the videos ive been following, which all show the same wiring. You connect smoke detector output to a relay with 'signal 1' and 'set state' meaning if detector sends 0 (meaning no smoke) it shuts down whole relay and any signal is blocked until detector sends a 1. From Official Barotrauma Wiki. It's for any kind of input handling. 198 votes, 58 comments. #footer_privacy_policy | #footer. Sadly I do this, I might give you DIY reactor controllers and special ballast tanks but sometimes if the railgun happens to trigger 2-3 C-4 Denotators that were place literally 10-15 rounds ago that "Wasnt" meTrying to start a solo campaign, Tried both with the Barsuk and Dugong. Which would be a linear decrease in fuel consumption, however this isn't the case x is a function of y and when we increase the number of rods we. and even with the commonly used 5 component reactor controller you can still slightly overload junction boxes, so batteries can be used to smooth out devices that are intermittent to help prevent that. Pathfinder = Tier II Scout sub. Anyone could replace a fuel rod. . Best. I was mastering my reactor job as engineer for a few missions, came up with keeping temperature at the minimal possible level to produce energy to save rod/rods charge, so I was keeping temperature level equal to the lowest orange temperature bar and, of course, was adjusting turbine output to stay in green zone. The battery then powers the junction boxes directly. . Barotrauma. This design in my limited testing has proven robust and universal enough for me to feel comfortable sharing. EDC timing and reactor controller are also important. Outposts never use those, and reactors can emit radiation if their shielding is poor, this might be a programming issue in the colony editor where they set the radiation shielding too low. This guide does not build a turbine controller. 0. we used it once and went back to typhon 2. For divers that can mean burst eardrums or drowning. Rewiring Components to Reactor. if u truly want a carefree reactor with overvoltage protection, u would also need a battery buffer. The only required user input is to type new reactor max power in the controller's terminal if you decide to. This makes it great to control your reactor from overheating! Manual Control. Kudos for including some earlier versions!With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. I am modding a ship to use for the entirety of a multiplayer campaign. I expanded upon Ignis' DIY Reactor Controllers, and added 4 new reactors. 2 is enough for full power, but a set of 4 rods with varied amounts of durability will allow you to replace them 1 at a expired. The dev team has effectively neutered ALL (AND I MEAN ALL) custom auto reactors down to the shitty vanilla auto reactor. So me and my friend have just recently started the game, however I (the sub engineer) run in multiple issues with the reactors both in the Dugong and Camel, where automatic control wouldnt work and the reactor would always scram, and so I had to manually control it, and there were some huge dips and spike in load constantly, going from 4500 KW all the way into the 2000 KW in a span of a second. 2. Play with friends, strangers, or your worst enemies. signal output should be a. Obviously you put smoke detector near reactor. the dev team doesn’t like reactor controller so in general isn’t that powerful: you will get undervoltage and overvoltage. I swear to the old 2-component bang bang controller. Being. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumNot so, this is a reactor controller that works quite well Formulas are Turbine output = Load value / (0. 5-component is frequent version that will prevent many issues with reactor and allow have much less over/undervoltages in general. Second, overvoltage can be a good thing now. Pretty cool. This is all about Barotrauma – Guide for Ship Reactor for Better Automatic Control in Barotrauma; I hope you enjoy reading the Guide! The " Carnot " Component System is very modular and this is the simplest, while at the same time effective, module. Remora: 5000. It's easy to wire. In short, there is no easy way to stealth, and if you're in too narrow of a tunnel you may have no choice but to barrel right into enemies. PID (proportional, integrative, derivative) is a general logic mechanism used for automated system control. 74 votes, 29 comments. A reactor controller circuit will also help, I recommend the widely tried and tested five component as the most efficient and reliable one, easy to set up too, though there are more interesting and complex ones out there that can make the engineering aspect of the game much more fun. 13. 9. Windows in Barotrauma are actually two-piece items, consisting of the background and the window frame. Despite the sliders being instant for humans to adjust, the intended manual control of the reactor remains unengaging and lacks complexity. So for gaming core number doesn't really matter. 1. To create a node select a wire you wish to bend and hover over a section over it,hold control and click on a part of the wire. It takes 25 seconds to go from turbine 50% to 100%. While the reactor needs constant adjustment when there are times where more and where less power is needed, the supply by the batteries is steady to the grid. Shutting down the reactor doesn’t automatically turn off automatic control. an assistant put 3 fuel rods in the reactor all at the same time). Rewire door buttons so they open different doors, easy traps. No4Delirious [author] Oct 20, 2021 @ 11:57pm. It reacts very fasts to load fluctuations which helps to prevent overvoltage and runs reactor at critically low temperature which saves a lot of fuel. High load from external sources can still cause the reactor to overheat and potentially meltdown with that 5-component circuit, depending on reactor upgrade status and how many fuel rods are in. The battery rarely takes damage because of the logic control, and the junction boxes rarely take damage as well because batteries update their output almost. Barotrauma > General Discussions > Topic Details. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. Nuclear reactors will overheat once you insert more than one fuel rod in. Toggle Inventory in Sub Editor. Automatic reactor venting. Barotrauma is a game of complete chaos in a stressful and volatile environment. I've been using a similar setup on all my subs for a while now. ago. Place your !explosive in there 3. Written by No4Delirious. So assuming a steady 40% fission rate: (. When I tried to fix this using a reactor controller, I found that it completely negated ANY interaction with the reactor at all. You can liken it to the cruise control system on a car, controlling the accelerator to maintain a certain speed. You can alter the expression of the REGEX component [1-x] to be as high as 9. It used a logic control system to make sure the output of the reactor always matches the demand of the battery it is connected to. An engineer could fit a reactor controller circuit but in general I think this should be for quality of life rather than an essential thing, i. The Greater Than Component compares the power and load of the reactor to control the turbine. New Hoist the Sails Reactor Controller | Barotrauma FailroadExpress 2. Safe operating temperature of reactor is between 4000 and 6000, by default internal automatic mode will set temperature at 5000. These screenshots were taken at the beginning of March when I was ranting to a friend of mind about this exact same thing lol. >Plays Solo. Here are some things to consider. :) Something like if temp greater than 5000, then divide the fission rate by 1000, else leave it alone with denominator of 1. I can upload screenshot if needed, but my wiring and components are the same as all the video, so im curious why nothing is happening. Typhon: 5000. #1. Please feel free to leave questions in the comments below. How to instantly to blow up reactor without melting - barotrauma sabotage / traitor tutorial. Fixed anaparalyzant not reducing paralysis. I have seen maybe one or two reactors that actually do this and they are a bit complicated and resource heavy. 11) This guide first explains some advanced features of the Barotrauma reactor system and then combines a PD controller with some reverse engineering of Barotrauma's source code to build a working fission controller. You can alter the expression of the REGEX component [1-x] to be as high as 9. Latter is what must have been broken. Knowing the current maximum output of the reactor can be critical for custom control circuitry, also knowing things like oxygen generator output and engine power usage and thrust could also be useful. 4)/2 = . Fire can also occur from exceeding this temperature for a different, often smaller timer duration (these durations can be found in the editor on the nuclear reactor entity). Some ship builders make a logic circuit using a memory. ago Wait the bots know how to operate it now? NoahKino • 5 hr. I wire the battery charge % to the display above the battery. it's just the normal 7 (or 5, if some math is pre-done) controller, I'll build a comparison setup for both tonight (if I have the energy). Next time it happens, ask around and see if anyone did anything that might cause a sudden drop in grid load. Load buffers will become more important. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. When the components are correctly configured the sliders will bounce between 0 and 100. I say almost, since it due to the way reactors interpolate the actual system load, achieving instant response to the actual system load is near impossible. 875 is then inserted into SET_FISSIONRATE, thus making the reactor operate at 46-47% fission rate, depending on the rounding. (The sub is a standstill so don’t worry about the Output alert) That is my usual 4-rod manual control. Barotrauma - Orca class submarine overview. 3 of them are new reactors made by me, and 1 of them is the famous two component reactor. Remora. it uses an PI controller to manage the reactor load. In control theory, a bang–bang controller ( hysteresis, 2 step or on–off controller), is a feedback controller that switches abruptly between two states. A Workshop Item for Barotrauma. A tutorial on how to set up wiring for power in Barotrauma the game. Wire door to delay fuse to transmitter that transmits on the same frequency as "reactor off" frequency to cause confsion. Reply. Stop the Orca 2 to a halt, maintain position, lower the charge rate of Super-capacitators and Batteries, and then you should have enough power for the Fabricator. steamcommunity. Welcome to Europa!. You said it happens every 5 minutes, it’s most likely due to an action by one of the crew. Not my setup, but a simple reactor controller: Need: Greater than component, regex component, 5 wiresSo long as the pump is >25% durability, the reactor operates kinda sorta as it normally would. Obviously you put smoke detector near reactor. com. All Discussions. The power management for the Orca is a bit crummy by default, I think the most effective way is to force the batteries to just buffer the reactor output, put it in manual control at 2500-3000KW and leave the batteries enabled at 100% charge rate, they should buffer any difference. However, I have found stealth to be helpful all the same in coping with the high enemy densities of high level zones. For example, using 4 of the same type of rod just causes each rod to lose durability at 1/4th speed. Operate complex on-board systems and devices like the sonar, nuclear reactor, weapons, engines and. I definitely agree with the first comment, however. Trust me it'll save lives. A few seconds after undocking, an AI engineer starts the procedure of switching the reactor to automatic without being ordered to do so. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. Athena. Well this is new info to me. You could test this by. Investing on electrical maintenance upgrades and crew/talents can also help since that electrical room can easily flood. Recently I saw a guy who using 5 components such. Giving engineering more to do inside their. This video covers:0:00 Overview0:46 Wiring basics1:38 Junction Boxes Breaking2:11 Why yo. First, good component based reactor controllers are still much better then built-in one. ago So got back into the game for 1. 1 / 3. by McD's. I am modding a ship to use for the entirety of a multiplayer campaign. Barotrauma. Quote from another discussion: *** The reason they were nerfed was simple The Bang-Bang Reactor Controller With only 2 Components, A Greater Component and a RexEx Finder Component, and 5 wires you can make the most busted auto reactor from the start of the game if you're lucky at your starting station. A submarine file containing pre-wired assemblies for new-style Magic Reactor Controllers for your learning pleasure. Thing is, the part of the adjustment process on Manual Steering mode is depending onto the character's Helm skill. Most of the doors and. What this means is that the System won't be active at all times but only when bad things happen (e. Although I suppose as long as you aren't the one doing the. Refer yours to another sub in builder. The general stairway structure of the sub allows for easy descend into reactor and engineering compartments. Typhon: 5000. Q. Just pop in rods, turn off auto-control and never worry about the reactor until the rods run out of fuel. Collection of short tips for every class and some class variants too! <!---NUCLEAR ENGINEER TIPS---> 1-Most devices only require half the energy (required voltage is 0. Focusing on ease-of-installation for missions and fuel efficiency and other upgrades for campaigns A turbine control can be done very easily with 2 components. I would suggest a greater than component in the temp control, that seems like what is happening. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. The Herja has a decent power draw from its twin engines and if you're working with a default automatic reactor and not taking care with your piloting, it's real easy to set the ship afire by overvolting your boxes. This workshop page was mainly created to serve as a user manual for this controller, since i use it on a lot of my submarines. I have some safety circuits and a simple 3-component load balancer that does its job faster than any controller even before the nerf and saves ~25% fuel when i'm on the move. Go to Barotrauma r/Barotrauma. Dugong is a beginner-friendly, highly accessible sub. ) Then you have the REALLY good. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. If reactor is badly damaged wear a diving suit (PUCS grants high resistance) and stack with a hazmat suit and iodide potassium before proceeding as usual to prevent getting instantly fully irradiated/contaminated. I do not want to spend all my runs of this game managing the reactor its incredibly annoying since the devs do not make the regular reactor controller work by itself. Once it stops beeping, you're good to go 🤡. [1] Gesch. If you manage the reactor properly, you can power everything while keeping fission low and more than doubling fuel time. Credit for the 7-component controller: value (output=1; false output BLANK; use captur. This guide does not build a turbine controller. Flee or fight alien lifeforms, explore a. The reactor is giving constant power to the battiers, and the batteries are regulating the poweroutput automatically. When held, it shows the interface of the controlled Nuclear Reactor, including the conditions of its Fuel Rods. 2-You can control fission and turbine with movement keys. All rights reserved. And they don't have to be captain, you can set bots to do certain jobs by using the bars in the top left corner, and (in single player) change control. Wire door to set off C4 or IC4 on a delay fuse. Wire a fuel indicator. I like having my pumps run off a couple batteries so that even if things are FUBAR you can still at least. . 3. ago • Edited 8 mo. Simple Stuff: - Put info panels on the bridge about load and output of your reactor and fuel state. A Wreck is a sunken hull, usually a Submarine. Without it every time the reactor spiked down it would be an Over Voltage. © Valve Corporation. All rights reserved. if you wanted, you could create different regexes for different reactor outputs. Remora: 5000. 3. Data is potentially outdated: Last updated for version 0. #3. Livingmeme3. Community content is available under CC BY-NC-SA unless otherwise noted. This is a minor annoyance when using reactor control circuits. While the reactor needs constant adjustment when there are times where more and where less power is needed, the supply by the batteries is steady to the grid. So assuming a steady 40% fission rate: (. Automating turbine output control was easy, since it's just a straight percentage of max power out of the reactor. If a empty fuel rod is in the reactor at the same time as a full fuel rod, docking to a station will catch the reactor on fire. And if there are any - not for long. ) Then take a Divide component and have it Divide the current load by the recorded value. You can do this with a quick and dirty reactor controller. Reactor Controller Components. you only need 18. You are not logged in. toggle_state, set_state1:22 Relay (toggle)2:41 Relay. It started with the multiplayer version of the Iroh's Bang-Bang Reactor controller not working, so I went in and replaced the reactor controller with one that does, and published it for people to use. Its only taken me an hour to master this. Although I suppose as long as you aren't the one doing the. Although I suppose as long as you aren't the one doing the. 19. These accept percentage inputs (0 to 100) and set the corresponding reactor slider to that percentage. If reactor is badly damaged wear a diving suit (PUCS grants high resistance) and stack with a hazmat suit and iodide potassium before proceeding as usual to prevent getting instantly fully irradiated/contaminated. 4)/1 = . com So got back into the game for 1. The battery rarely takes damage because of the logic control, and the junction boxes rarely take damage as well because batteries update their output almost. Don’t be scared of the manual control. Which is way less exciting than sitting on helms driving the sub. . The Bang Bang reactor controller not working for you in the Hoist the Sails update? Here's Jash's best fix for the latest version. The battery area is directly connected to the reactor, and has an energy loop to prevent it from collapsing when the batteries are filled. Important: Add behavior logic to the. Barotrauma. Your issue is probably busted junction boxes, meaning that the power can't route from your reactor to your pumps because the interlinking junction boxes are completely broken. In your picture it looks like that sub's reactor has a huge max power output. 19 Dip2pot4t0Ch1P • 6 hr. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. You might be able to put more than one word before the expression, I'm not sure if I tried that already, but grabbing two values from. Try the DIY Reactor Controller, especially the 7 part one. r/Barotrauma • Me managning reactor while the capitan has. It was a catastrophe we amazing pulled back from. github. Add a Comment. This is a vanilla item assembly that works as improved automatic control for reactors. 0000001 seconds. Orca: 3500. 0. Details File Size: 4471KB Duration: 5. Remora. Yes, you should adjust the value when upgrading reactor's max power, however in most cases the difference is small enough that not updating the value won't outright break the controller, just make it provide a bit less power. Barotrauma – Component Based Reactor Controller. If I remember correctly, the problem with high-performance reactor control is that reactor output terminals seems to have inherent 1-2 frame delay in them. All three on board characters; Captain, Electrician, & Mechanic, when interacting with the Reactor only saw the fuel rod slots, as though the reactor was nothing more than a Fuel Rod exclusive 1x4. #4. The load on your reactor is 0, so the automatic control is keeping the output at 0. First, good component based reactor controllers are still much better then built-in one. :) Something like if temp greater than 5000, then divide the fission rate by 1000, else leave it alone with denominator of 1. Tab ↹. When I activate the battery the magic controller of the reactor usually adjust the reactor's power output to the load which is reduced by what is covered by the batteries. 2. Typhon 2: 5000. I've added a section with answers for your other questions. If you stagger the rod insertions you can replace empties without risking a power loss. In Barotrauma terms--on an in-game reactor, SET_FISSIONRATE and SET_TURBINEOUT are both parameters that can be controlled by. As long as the reactor is active, every other connected device on the ship will remain active as well.