Ciena 6500 configuration guide. Hi Paul, if what you are trying to do is start fresh, almost like a factory reset, then I believe the only way to do that is with a tool that only Ciena support engineers will have access to, so you would need to request that support. Ciena 6500 configuration guide

 
Hi Paul, if what you are trying to do is start fresh, almost like a factory reset, then I believe the only way to do that is with a tool that only Ciena support engineers will have access to, so you would need to request that supportCiena 6500 configuration guide  Choose the window size, which is the size of the virtual screen of the VNC viewer

1 and 10. conf logrotate_original. Global parameter list. Step 2: Select Node Information from the Configuration drop-down menu. . 6500-2 6500-D7 6500-S8 6500-D14 6500-S14 6500-S32 6500-T12 6500-T24 Figure 2. Step Action: Enabling Air filter replacement alarm. 2 6500 RA logs can result in 6500 management issues. Command one would want to run to upload a config to a device. Hi Vikash, the command I mentioned above is only related to 6500-PTS. a Layer 0 project has been committed in MCP. View and Download Ciena 3930 Series hardware installation and start-up manual online. 255. Network Element should have ISIS (or any other IGP protocol) commissioned and SR Enabled. x. What’s inside. Access the Ciena Portal and follow the steps below:  Step 1: On the left vertical bar, select Knowledge. OneControl : 8700 and 5170 nodes are constantly resyncing; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance. Then locate the product and SAOS version. With the ability to provide on-demand connectivity and terabit switching, you can continually stay ahead of unpredictable customer demands with Ciena’s 6500 T-Series Packet Optical Platforms. The interfaces are listed in a table on the tab. Here we have configured a Aggregate and this is also in LACP configuration. OneControl : 8700 and 5170 nodes are constantly resyncing. From MCP 5. BIP. conf logrotate_original. Provides advanced Carrier Ethernet and low TCO, powered by Ciena’s SAOS. conf file, as required. 2) (ciena. Ciena 6500 Packet-Optical Platform 4x10G 2. Create a copy of the logrotate. For the purposes of this. For additional details and support for configuring MCP to use this non-default MCP configuration, contact Ciena. Name—Enter a name to identify the VLAN entry. Checking the system state of Site A and Site B. 6. Ciena’s 3948 is a cost-effective router designed to address the requirements for higher capacity and end-to-end disaggregated IP services at the network access, supporting 4G network evolution, 5G deployments, enterprises, and next-generation business services. These tables are to be used by the reader as a quick reference guide for terminology definitions. Ethernet Segments details. Internal Driver Name: Ciena6500; Driver Package: Ciena6500. Configuration without CKN key-string behavior change: Device# configure terminal. The MCP provides the ability to enable/disable PM statistics on L3 VPN endpoints (VRF IP interfaces) at the time of their provisioning. Step 3: Remove the power. . Step 7. The chassis installation kits and cable guide contents vary between chassis. 6500-S32 packet/OTN switched configuration with integrated three-way ROADM . Click the Export network button and save the mcp-export-<current date and time>. 6500 Packet-Optical Platform. For more details you can also refer the guide "380-1880-810_(5170- 5171_SAOS_8. Figure 1. Maximizing networking efficiencies, the 6500 converges packet, OTN, and flexible. To enable multi-zone traffic at the top-level domain of the configuration hierarchy, select Add > Domain then select Multi Domain Traffic. Step 2: At SNC originating node Edit the SNCG and change its Primary State from IS to OOS. Go to Configuration, Backup and Restore. lukman hakim. Table 2. Enter the name in the Name field exactly as it appears in the 'Key and Name' column in the preceding table. Figure 3. I have a 6500. Operators can leverage both photonicUsing a text editor such as vi, open the patch-lineup-hostadd. License Server: "Floating IP" onto a pair of LS in HA is not responding. Steps. It provides highly dense. conf file. 8110. In a multi-unit deployment, you must configure the settings for each unit individually. • Ciena’s vSwitch is a Data Plane Development Kit (DPDK)-based switch that provides service function chaining as wellFigure 1. set ciena-6500r-system:system id member [name <string>] Step 3: Logout and log back in to the shelf to confirm if the system name got updated. Hi Ciena SME, we have two DWDM Ciena 6500 with follow configuration: CIENA 6500 Packet Optical Platform running software Releases 12. thanks in advance. In the MCP UI, select System. Installing the Ciena Linux system bundle for Site B; Importing license server certificates; Static IP. Using the MCP UI, select Network > Network elements operations. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the. 2 card-based packet/OTN switching hardware is available for. PinPoint requires that either a SiteIP or a southbound IP address must be defined. Multiple configuration options with fully modular 4-slot or 10-slot chassis variants. Tech Touch Video: Live Chat Demo. Ciena’s 5164 Router is purpose-built for 5G networks that converge 4G/5G fronthaul, midhaul, and backhaul (xHaul) networks onto a common, simpler infrastructure. 6500 - planning guide. Select displayTimezone. Utilizes 1. The following topics for non-DOC-controlled systems: Topology Fundamentals Photonic Optical Control Photonic Applications Photonic Engineering Rules Photonic Set-Up Guidelines Provisioning Examples See Part 1 for the following. The Performance Metrics or Performance Monitoring (PM) microservice orchestrates the collection of metrics from resources. 6500 Packet-Optical Platform. With the ability to provide on-demand connectivity and terabit switching, you can continually stay ahead of unpredictable customer demands with Ciena’s 6500 T-Series Packet Optical Platforms. Packet collection is supported for Ciena’s Service-Aware Operating System (SAOS) 5100 Series version 10. Ciena 6500 | OTNStandalone License Server: 6500 Network Element fails to get license from License Server License Server: not able to add "Floating IP" onto a pair of LS in HA. Table 1. Choose the MCP UI > System tab. Installation - 14-slot Shelves Release 12. Regards. For detailed instructions regarding the installation of Site Manager, see Site Manager for 6500 Packet-Optical Platform and Common Photonic Layer Fundamentals (323-1851-195). Under Security, select Configuration. The 6500 S-Series shelf configurations are equipped with an agnostic, centralized packet/OTN switched fabric, scaling from 600Gb/s to 3. (There are guides for the 4200. Table A-3 950 W AC-Input Power Supply Specifications . Service Delivery Switch. Operators can use this powerful tool to identify and localize high connector losses or reflections and ensure Figure 2. The Brocade was providing R_Rdy, Ciena was simply doing pass-through. 06. single command to install; auto configuration • Line interface – 2 x Wavelogic3 Modems with a 200Gbs port , 16QAM DWDM channels, C -Features and benefits. ajay m (Customer) asked a question. Security Configuration Guide, Cisco IOS XE Fuji 16. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. Sole title to the Software and documentation, to any derivative works, and to any associated patents and copyrights, remains with Ciena or its licensors. x two-point E-Line services. Offers. Save the patch-lineup-hostadd. From 800G performance optics and 400G coherent pluggables to control plane automation, you can seamlessly maximize your investment into the future with. The 3922 features a cost-effective 24 Gb/s switching fabric capacity, supporting two 1/10GbE and two 100M/1GbE fiber ports, and two 10M/100M/1GbE copper ports. The FR configuration section appears. OME6500 (All Platforms) : Alarm Clearing Guide. XDMCP (X Display Manager Control Protocol) opens a single port in this range. Collector CLI command. . 1_(6500_R13. It shows the mac. Steps. Autoranging input with power factor correction (PFC) Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. mac show. Ciena reserves to itself and its licensors all rights in the Software andRetrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. x) When configured with SAOS software stream 10. Provides advanced Carrier Ethernet services powered by Ciena’s Service-Aware Operating System (SAOS) Supports two 100/1000Base-X SFP ports and a combo port supporting 100/1000 Base-X SFP and RJ-45 10/100/1000Base-T. Site Manager hardware requirements; Site Manager port requirementsExcerpt from the Photonic Layer Guide, part 1 (NTRN15DA) In the Site Manager Configuration -> Equipment/Facility Provisioning screen, the Tx/Rx adjacency of the 6500 CMD port must be edited to the type labeled. The 6500 S-Series shelf configurations are equipped with an agnostic, centralized packet/OTN switched fabric, scaling from 600Gb/s to 3. Preview. To turn off paging =. I need the User guide for the Waveserver Ai product not Waveserver. Respond quickly to increasing end-user demands with on-demand connectivity, and scale to terabit switching capacity for efficient switching of 400G+. Link: A Link represent the unterminated transfer of. For further reference of 6500 " Lower layer GCC implementation rules" please refer to this handbook 6500 Packet-Optical Platform Planning, Part 4 of 4, (NTRN10DB). Ciena’s 6500 Family of Packet-Optical Platforms enables you to stay ahead of unpredictable customer. Installation kits and cable guides for each Catalyst 6500 series chassis are listed in Table 1-2. MCP Documentation. It is supported for SAOS 6. License Server: License check request timed out. Liquid Spectrum’s advanced software applications leverage Ciena's Manage, Control and Plan SDN domain controller and open APIs to abstract complexity associated with advanced flexible technologies, enabling operators to fully operationalize and realize the benefits associated with a. VPLS is the default value assigned to E-Line services if the BPO-IFD file is not altered. Pre-requisite: Restoration DLT/DTLSET should have created at originating node under Configuration-->Routing Profiles Step 1: Identify the SNC & SNCG which are down due to active fiber cut in network. STEPS: Login to MCP as a user having Security Admin privileges. Configure the following settings. Brocade Compatibility Guide for FOS v7. Expand Post. Search through the response looking for resources whose orchState=failed. We are covering Ciena 3900 series (3902, 3916, 3920, 3930, 3940, 3960, etc. All worked fine until three weeks ago suddenly the traffic dropped and there was no traffic between the ISP and the local network. WLAi FOTR module . Profile (v3)—Choose the SNMP v3 profile, if SNMP v3 is used. 5 (or later) customer documentation to add new ROADMs and perform system lineup and testing (SLAT) based on the. This includes 5400 NEs with embedded SONET/SDH services as well. This enables one to perform service assurance and stats collection on those endpoints. BIP. mac show. these benefits across 6500 hardware that supports compact WaveLogic 5 Nano 100G/200G CFP2-DCO pluggables. Depending upon port configuration and which version of the platform is being used, a single. Completing the configuration of the MCP. All tasks in this section start on the Geolocation Setup/Configuration page. required port configuration setting for the Brocade to properly interact with the 6500. Release 12. Waveserver Ai User Guide, Release 1. Edit the logrotate. Power and Heat Numbers. 2. The following is the sequence of steps performed for 6500 upgrade in MCP: Download 6500 software from to a file server. ISL port set to 8Gb to Ciena 6500 using standard Brocade shortwave SFP. To offer flexible, cost-efficient deployment options, the 6500-D14 is tailored for photonic/transponder applications combined with muxponder card-based packet/OTN switching, while the 6500-S14 can also be optimized for packet/OTN centralized switching deployments, with the ability to tune for packet and/or OTN in any ratio. 6500-T12 shelf equipped5171. If these files are ever misconfigured, or if you need to restore the default files, you can always delete the current file and restart Nagios. ROA collects the following information: IS-IS, OSPF, BGP, BGP-LU, IP-VPN, L2 interfaces and Segment Routing LSPs. What's the. Figure 2. Using a text editor such as vi, open the logrotate. • Plug and play easy to install product – single command to install; auto configuration • Line interface – 2 x Wavelogic3 Modems with a 200Gbs port , 16QAM DWDM channels, C - band tunable, Capacity - 88 channel - 50GHz grid • Client interface – 10xQSFP+; 4x10GbE ( 10GBase- R) and 40GE ( 40GBase- R4) ; 4xQSFP28 Features and benefits. raciena6500. 6500. The results of the simulated link failures appear in Failure. Ciena OME 6500 devices, OS version 10. 5” or 10 x 2. Guidelines for. Zones are configured underneath the top-level domain. Pre-upgrade 6500 NE either Now or Schedule to be executed at a later time. The Catalyst 6000 series switches (Catalyst 6006 and Catalyst 6009 switches) are described in a separate publication, the Catalyst 6000 Series Switch Installation Guide. This is from the Installation/Ordering documentation for the 6500 32-slot shelf (if you ordered from Ciena): Included lugs are Hubbell/Burndy p/n YAV2CL2NT10FX90 (Copper Compression Lug, Narrow. This configuration is a server-wide property and applies to all photonic service provisioning. For more details on the command line, please refer to "323-1851-193_(6500_R12. I have connected console port to an Open gear Terminal server. Thanks in advance! Interesting tidbit from the wikipedia article on the company: "In 2010, Ciena bought from Nortel Networks its optical networking and Carrier Ethernet business for $774 million. From 800G performance optics and 400G coherent pluggables to control plane automation, you can seamlessly maximize your investment into the future with. The Brocade was providing R_Rdy, Ciena was simply doing pass-through. MCP5. The 3928 is purpose-built to provide Layer 2 and Layer 3 services over carrier-gradeIf you are running Layer 0 Control Plane then do not follow this guide, if not, follow the steps below: Step 1) Check the ADJ-TX facility on the CMD related to the DOC domain. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical Support. Tailored to address enterprise business requirements at the edge, the 6500-D2 Packet-Optical Platform is a compact 2RU chassis that cost-effectively extends the flexibility and resiliency of the 6500 platform from the core to the access. Is this configuration supported?Ciena (NYSE: CIEN) has expanded its 6500 Packet-Optical Platform family with the new 6500 T-Series. In 6500 14-slot shelf, you cannot check complete configuration via single command. 6500 Troubleshooting Guide P a g e 13 | 17 11. 38 nm for a total of 4825 GHz of spectrum. MCP: Policy management for updating license server on network elements. 24/7 in-flight data protection with wire-speed encryption As part of Ciena’s multi-layer security approach that ensures the confidentiality, integrity, and availability of data in the network, the 6500 offers advanced integrated AES-256Network Configuration Manager helps you manage the device configuration of Ciena Switch. To consent to receive all cookies on all Ciena websites, click I acknowledge. The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to full rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per. Attachment Circuits attached to the EVIs. System Configuration—Select this. Step 2: Run the following command, where the name can be up to 32-charecter string. I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. S onver f w requir ore. Step 4: Find the Control frame profile parameter and select the desired profile from the drop down menu and click. Please refer to the document (Waveserver_R1. 7)Stay ahead of demand—todayand into the future. BICSI. Use the VLANs tab on the Admin > Units page to configure VLAN interfaces. Ciena’s 8700 Packetwave® Platform—a multi-terabit programmable coherent DWDM packet switch—addresses the growing need to efficiently aggregate and switch large quantities of packet traffic while guaranteeing stringent Service Level Agreements (SLAs), revolutionizing the capital and operational. 15000 THz/1528. Mac hardware running OSx 10. Note We recommend that you save the packaging material for use later if you need to move the chassis. AIPA Install Procedures; Creating the bpadmin user;. Zones are configured underneath the top-level domain. Service diversity and flexibility with the 6500-D7/S8 6500-D7 Optical Type 2 with AC power Cost-effective WDM configuration with ROADM 6500-S8 Packet-Optical with DC power Compact 600G Packet/OTN Switch This capability supports DCN Example 4 in the 6500 Packet-Optical Platform Data Communications Planning and User Guide, 323-1851-101. 6, Issue 2 - Free ebook download as PDF File (. Bias-Free Language. IfdConfig". 49K views Top Rated Answers All Answers Amit G1 (Customer) 5 years ago Please use this link and under product documentation - ALL PRODUCTS. @Note: Please make sure that third party network are transparent for GCC1 and GCC2. Local authentication is always used as a fallback in the event that authentication through a remote. the 6500-D7/S8 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with packet/OTN switching and an intelligent control plane for cost-effective. You can use the Market REST API to assign a node role on a device for the first three steps in the process and the Network element (constructs) REST API for the fourth and final step in the. Ciena’s 3926 versatile and compact CPE that delivers 10Gb/s service delivery of PON, IP and Ethernet, and flexible modular add-ons for TDM, and network functions (VNF) of business or mobile backhaul services – now with L2, IEEE 802. Using the MCP UI, select Network > IP transport. Stay informed and get Ciena's network insights emailed straight to your inbox. Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. Collection of L2 interfaces using yang. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots enabling customized. The configuration hierarchy organizes components in a tree structure, with each branch representing a different part of the configuration. New in this release and documentation roadmap Installing 6500 14-slot shelves Installing OMX, fiber manager, DSM, passive equipment, and routing/connecting related cables. 14. The Cisco has a portchannel configuration in LACP which end's up in a Virtual Switch configuration in the Ciena 6500. OneControl : 8700 and 5170 nodes are constantly resyncing. Memory: 8 GB 1333 MHz. If network elements were enrolled and synched before the scale was adjusted then it is recommended that a re-sync be performed on all network elements that participate in timing, from the Network > Network Elements page. Use the values in MCP-generated alarms to set or change the alarm severity. Resolution/Answer. 0-certified for E-Line, E-LAN, E-Tree, and E-Access for improved service offerings; E-Line and E-Access up to and including 100GbE. Installation Guide. Ciena Operational Commands. 5K. you can search when your in the chassis for possible commands. Cisco compatibility matrix request to check this with DWDM vendor compatibility matrix and I don´t found at Cienna support portal the Ciena compatibility matrix with Cisco SAN Directors . • Viewing the Configuration Hierarchy. Observer: basic visibility of network elements and. Steps. IP Router Configuration (SAOS 10. 0 mode is incompatible with MCP deployments, which uses both C and L band photonic services, since MCP internal model will have a common OTS layer, but separate C and L band OMS termination points and associated forwarding entities. Features and benefits. 3_Command_Reference)RevisionA. Top Rated Answers. Pages 100 This preview shows page 69 - 73 out of 100 pages. 00. 3930 Series switch pdf manual download. Ciena’s 6500 Packet Transport System (PTS) addresses the growing need to maintain profitable delivery of TDM services while future-proofing investments to an all-packet network modernization. . REL. Not for 6500 packet-optical shelves. Regards, Jojo. 365 of the U. All Catalyst 6500 series chassis can be rack-mounted. MCP provides a list of configurable parameters that are used for allocating SIDs. The Routing/Label distribution protocol setup (ISIS/ISIS-SR/LDP/OSPF) must be available. Step 4: Select the row of the required shelf from the Node Information table. Completing the configuration of the MCP email service; Disabling the configuration of the MCP email service; Disabling Storage of Rolling Alarm Mutations; Enable license server data distribution to network elements; Web-based Site Manager installation. of whatever Brocade sent (primitives, data frames, etc). Procedure to replace a power card in a 7 slot 6500 chassis. Data sheet Watch video. Download >> Download Ciena 6500 installation guide Read Online >> Read Online Ciena 6500 installation guide 24 May 2013 Our customers recognise and value the benefit of consistent installation quality across all their sites. Ciena Commands. Hi @Brian W1 (Customer) You can find this information on e. x states Ciena has passed responsibility for providing the. where <version> is the application solution (MCP) software version. -) partition (required if config was created using a partition) group (array of groups in same order as were while creating config) (required if config was created using groups) Example. Hi, We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. The Ciena 6500 Packet-Optical Platform is a multi-port multi-protocol system that supports TDM/WDM/GigE/10G/40G and 100G ports. x: Manual CTX switchover causes all LM modules to reboot;. 4(2e) at 4Gbps speed ports. Repeat on Site B (standby MCP) if one has been configured. IS-IS Recorder Settings. EQUIPMENT_REPORT: Provides a list of equipment present in the network. Catalyst 6500 Series Switch Installation Guide . Schematics and illustrated parts list can also be included. I have several 6500 interfaces to Juniper gear that will take a "flap" where the Ethernet feed to a QSFP28 optic RXs errors and stops in one direction for 3-4 seconds. 16 Sep 2015. Installation Guide. This port is opened when VNC displays 2 through 10 are enabled; however, access control within the xdm (1) configuration disallows any access from remote machines. Command. Maximizing networking efficiencies, the 6500 converges packet, OTN, and flexible. Installation. x, the 3928 operates as an IP router supporting NETCONF/YANG to enable an open SDN environment with full visibility via telemetry and automated provisioning using open APIs. 2 Tb/s of unrestricted hybrid packet/OTN switching for an. Click Edit at the bottom right of the page. 18. com. I checked in the Admin and installation guide but I did not find it. The 6500 Packet-Optical Platform (formerly called the Optical Multiservice Edge 6500 or OME 6500 during the product's time at Nortel) in telecommunication, computer networking and optical communications is a Multi-port multi-protocol system designed by Ciena that supports TDM / WDM / GigE / 10G / 40G and. L1 (SONET/SDH and OTN) control planes uses the following key terminology:. VPWS indicates that this is a Virtual Private Wire Service. 3806 XGS-PON Weatherproof Optical Network Unit. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. From the Waveserver - 6500 interworking NTP: For more information on the Waveserver, including installation and system configuration, refer to the Waveserver User Guide,. ROA supports routes mentioned in RFC 7432 in 20. 1 . Viewing the geographical redundancy status. I have searched the "maze" of technical documents on Ciena library but can't find. Perform the following steps to create a backup maintenance profile using the MCP UI. rdp; Driver Tier: 1; Vendor: Ciena. The available reporting API calls support the generation of the following reports: ALARMS_REPORT: Provides current alarms present in the network. License Server: load license fails after Registered Server transferred from one account to another in Ciena Portal; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. we use 6500 GNE configuration with redundant ARP GNE. To perform a manual OTDR trace, complete the following steps: Step 1: Click on the Configuration tab in Site Manager. 1. Table 1. 0) Public_IPV6_v1 (6500 specific policy)Ciena 6500 with module Card 4X10G OTR 4xXFP/4xSFP+ Brocade switch is 16Gb DCX 8510-8 at FOS v7. Increases total fiber capacity with increased spectral efficiency and support for C- and L-band. BIT. OME-6500. Ciena6500. In MCP a Node maps to a single physical device. Installation Guide. 6500 : Module/Card Replacement Guide; Environment. Adaptive IP Guide. In the REST API documentation (see Procedure ), open the API panel for GET {MCP_SERVER}/resources In the resourceTypeId field, input "ifd. 8 Tb/s, with a minimal footprint and unprecedented operational simplicity. Creates the lowest TCO at scale using Ciena’s Zero-Touch Provisioning. . This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. 6500. With dense 1/10/25GbE to 100/200GbE aggregation and support for both hard network slicing (FlexEthernet) and soft network slicing (Segment Routing), the 5164 is theLicense Server: License check request timed out. 3. WaveLogic Ai, the industry’s first programmable 400G, paves the way. I think there is a problem with the default route redistribution between the primary and backup GNE. 1 provided basic NE management (a. 3_Admin_Security)_Issue1. Each Catalyst 6500 series chassis ships with an accessory kit. Issue 1 10/17/2019 JPL JPL First official document release. Ciena’s 6500 Packet Transport System (PTS) addresses the growing need to maintain profitable delivery of TDM services while future-proofing investments toward an all-packet network modernization. never triggers an alarm in the 6500 just PMs. conf file by entering: cp -p logrotate. Edit the information in the fields shown in the table below, as required. Physical Interface—Select the interface from the drop-down list. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. Optionally Disable Soft Recovery Storage of Rolling Alarm Mutations. S. Installation. 7. 6. 5. Number of Views 6. On the Ciena Portal - Support / Documentation. When an E-Line’s MPLS mode is set to VPWS, the service can avoid MAC learning and can support internal loopbacks. No service management (no DVT or Prov’g for SONET/SDH switching) 6500. Step 7: Compare the "Laser Centering" configured on both ends, they need to MATCH. pdf) or read online for free. com to the customer site. Command. Packet collection is supported for Ciena’s Service-Aware Operating System (SAOS) 5100 Series version 10. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Generate commissioning scripts for a heterogeneous project (6500, Waveserver and Waveserver5). Table 3-3 Ciena products that interwork with 6130 Release 5. 6500-D7/S8 6500 Packet-Optical Platform Figure 1. The "Packet infrastructure" window displays, reporting the total number of services. Then locate the product and SAOS version. txt) or read online for free. On the Ciena Portal - Support / Documentation. 8G, 4x25G, WDM, SMF, 1310nm, 10km CFP2). Funcionality. Troubleshooting. What’s inside. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. It covers the servicing, maintenance and repair of the product. 16 Sep 2015. SITE-1 is directly connected to MCN (Management Communications Network) Shelf IP Address:. License check request timed out; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our. 71K. pdf. 2) (ciena. Technical Information Section 6500-S32 Packet-Optical Single onverged atform ddressing tworking requirement ro h dg h ore. From there, you'll find 6500 related folders and can drill down based on release and more. You can configure authentication to be performed locally or through a remote TACACS+ or RADIUS server. When the IS-IS entry appears in the configuration hierarchy, click the arrow to its left to display the configuration interface. 2 009-3218-022-Standard Revision A. Select Planning > Planning import/export. Log into one of the host machines in the clustered solution with userID root.