30mA Active RCD. Tony Goddard Screwfix Select. 5mm², 2 x 4mm² or 1 x 6mm² cables. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU location on cooker hood install Discussion in ' Electricians' Talk ' started by BodgeTheBuilder , Jun 14, 2020 . HandyAndy - really Mr. Or put in a. Hi all, I've installed an LED floodlight vertically above an FCU switch, and used some 25mm conduit and fittings that I already had. For example, in my kitchen I have 3 switches on a plate feeding the extractor, the main light and the gas hob ignition. #5. Lectrician Screwfix Select. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . There is no accessory correctly called a fused spur - it is just a common name for them. 1. to nearby 13amp fused isolation switch. Screwfix Select 1. com. Find your nearest Screwfix store and up to date opening times. The UK’s leading retailer of trade tools and hardware. £15. 99Inc Vat. To fcu, or not to fcu, that is the question: Whether 'tis nobler in the mind to suffer The slings and arrows of outrageous comments, Or to take arms against a sea of forum members And by opposing end them. 4. We offer safe deposit boxes in a variety of sizes to keep your important papers and valuables safe. then when the work as been done get my electrian to sign off & check it. Was taught that way must be 30 years ago. There is a $10 refundable key deposit on each box. com. Put one there specifically. PayPal accepted online. That's two cables on the 'load' side of the FCU. If the fcu is fused at 13A, can the 1. Schneider Electric Lisse Deco 13A Switched Fused Spur & Flex Outlet with LED Polished Chrome with Black Inserts (119FF) (2) compare. Flex going through a correctly sized hole in the wall looks much neater than a flex outlet plate. That FCU will then be connected to the TV socket and another socket for the virgin box. bearing in mind the supply is 6mm cable do you guys have. Free next day delivery available. On the load side connect a 2. com. networkgeeks New Member. That is why a w. Supplied with screwcaps and 2 x earth terminals for ease of looping. With Flex Outlet. 5mm cables plus your outlet to the hood (1. PAGE 1 OF 3. Buy Flex Outlet FCU Fused Spurs at Screwfix. From the settings menu, click or tap on 'Push Notifications'. FREE next day delivery available, free collection in 1 minute. Pay your way. 5mm swa. 0mm means you can only go radial, to create a split you would need a JB. Step 2 isolates the entire outside. Online Banking. Or under the bath, with a panel fitted that requires a tool (screwdriver) to remove panel (say for a shower pump/whirlpool bath)Bazza-spark Screwfix Select. In this case the boiler should be connected using a FCU (spur) and be a fixed appliance. The plug must be outside the zones, which usually means 3 mts away from the bath or shower, unless the cupboard is locked or requires a tool to open it. paaulyb New Member. Hi, just fitted a harok consumed unit in shed for lights n sockets, it is fed by new armour cable that is connected to an outside double socket, (which is fed by downstairs ring main) when turn on the main switch on the new unit it trips the RCD on. Stop Payment: Initiate a stop payment request at. This is about FCUs directly on the ring, part of the circuit. We'll that's what I've always used when I've done outside pond jobs. Option 1 looks good but you also need to consider rcd protection and also what's near to those fcu/sockets, like hobs, sinks etc. 4/5. - - - - Call 24/7 on: 03330 112. The UK’s. Coloumb Screwfix Select. View all: MK Fused Spurs. Click on the gear wheel. The spur both supply and load side have been done in 0. Terminal Capacity. A 6A MCB protecting the lighting circuit will trip a long time before a 5A fuse can blow. but having a FCU on a spur can cause problems, my dad decided to have a few sockets on a spur, and used a FCU. Pay your way. The current Screwfix Direct Catalogue reflects a range of approximately 15,000 screws, tools, fixings and accessories, which are being offered at more than 140 Screwfix branches throughout the UK. £79. #4. Hi, We have a couple of white appliances such as a dishwasher and tumble drier that have switched FCUs on the countertop and an unswitched socket below for the plug. #14. Requires 35mm Back Box. Put one there specifically. An electrician would be forced to have to hard wire it, run a 6mm2 cable from the consumer unit on a 32Amp RCD protected circuit specifically dedicated into a cooker FCU. Added protection against electric shock. The idea is that if the fan jambs it will draw excessive current which will blow the 3 amp fuse before the fire starts! seneca,May 16, 2015. Buy Black FCU Switches & Sockets at Screwfix. Order online at Screwfix. 5mm² cables. I was told by a friend that new regs require fcu`s on all appliances such as dishwashers, washing machines etc. Isolate power at your consumer unit/fusebox using the main switch. 5mm2 through wall to light. Break into the ring and connect a 13amp fcu. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesBuy Flex Outlet FCU Fused Spurs at Screwfix. 9A so both boiler and pump will happily coexist on the same fcu. 1. 5mm would not comply with 7671. 5 mm, providing it`s feeding a small load, the 1. The only way I can see to do this is to remove the cable from the adjacent double socket feeding the spur and to replace it with a plug and flex to the spur instead. The external sockets for the hot tub are at the exact opposite end of the garage from the LED light socket. Masterseal IP56 13A Sw FCU, at Screwfix Direct Masterseal range has been specifically designed for use either outdoors or indoors and in areas heavily exposed to dust and splashing water. Thread by: itisgeorge , Mar 16, 2022 , 6 replies, in forum: Electricians' Talk Cheers. Requires 35mm Back Box. Bazza-spark, Sep 15, 2023. Was to see if any one in the forum could see a problem. With RCD. Over 40,000 products. Assemble with other products into a modular front plate to create a grid. Hi Everyone, I need some help. Membership Eligibility. You can have as many FCU's or sockets as spurs off the ring as their are sockets or FCU's connected directly to the ring. com. PayPal accepted online. With Flex Outlet. The switched FCU fused at 3 or 5A feeds the lights. Raised Slim. I am electrical maintenance engineer, but have not done domestic work for a while. com. But if you then inserted a 9th socket somewhere in the ring, all of a sudden it would be OK, even though it is blindingly obvious that the mere. I always put a FCU outside the room and then a flex outlet in the bathroom but the job i refer to was a right pain in the * too so i opted for the easier option. 49 Inc Vat. Alaska USA operates 67 branches in Alaska, Arizona. Raised Square Profile. Screwfix customers rate this product 4. Discussion in 'Electricians' Talk. Now imagine a ring with 8 sockets on it, and 9 spurs, some or all of which are wired in with junction boxes. com. Risteard,May 16, 2015. FREE next day delivery available, free collection in 1 minute. With RCD. This will power things like my server and CCTV system. We offer a wide range of services at no-cost or at lower costs than traditional financial institutions, including more favorable rates on dividends and loans. Buy Fixings & Fastenings at Screwfix. Click & Collect. Buy Unswitched FCU Switches & Sockets at Screwfix. Passive operation. Sku: 01140302 More Options. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. Can’t advise properly unless you can be more specific. Home Forums > Screwfix Community Forum > Electricians' Talk > Isolator for kitchen appliances - FCU or non FCU. had the same with a heated towel rail fed from unswitched FCU bout 1 metre from shower head ,also a socket in a cupboard to charge up the electric toothbrush. A radial beats a ring every way you can think of. £ 1. Today I decided to refit an FCU in the garage which had come away from the wall. You are allowed 1 spur per socket on the ring. 5mm², 2 x 4mm² or 1 x 6mm² cables. 2m. PAGE 1 OF 7. If you want to protect the fan wiring with a 3A FCU or whatever, you could put a cheaper 2 pole FCU on the live/neutral feed to the lighting, saves the expensive of having a 3 pole switch just for the fan. Brass. So my new kitchen cupboards are 10mm less depth than the old which has created a problem for my plug in Intergrated oven. I’m not sure anything exists. All seemed quite normal but the socket in the garge had an FCU installed inline just before the socket. 842. I've no idea yet. UK call centre ready for your call 24/7. Backed-Out Captive Terminal Screws. Marine Credit UnionEnroll in Digital Banking. Many. Delivery 7 days a week. com. Discussion in ' Electricians' Talk ' started by ScubaCollie, Jul 2, 2021 . 5mm2 to 5amp fused switch >>> 1. PayPal accepted online. terrymac Screwfix Select. View all: LAP Fused Spur Modules. Screwfix customers rate this product 4. Once inside the shed put the swa inside a junction box and connect it to two 2. TTY (for the hearing impaired): 1-800-225-6378 or 541-225-6801. Terminal Capacity. If you wish to take more sockets, then you spur first to a fused connection unit (FCU) then on to the further sockets, you can have as many as you like down stream of the FCU but of course. . m. 30 day money back guarantee. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. Need Help. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. FlyByNight, Jun 29, 2021. Discussion in ' Electricians' Talk ' started by Bearbear, Apr 5, 2019 . Discussion in 'Electricians' Talk' started by Damodee,. 5mm² overload ? Mr. Have only seen FCU's taken from a ring as a spur then used as normal. 2. Order LAP 13A Switched Fused Spur Brushed Stainless Steel with White Inserts at Screwfix. Flex going through a correctly sized hole in the wall looks much neater than a flex outlet plate. Raised Square. Now remove both leads on backup battery & remove battery from panel. 5 mm. Take a spur off a socket above the worktop as a feed to the new single socket. Risteard Screwfix Select. 5mm², 2 x 4mm² or 1 x. Apple Pay accepted in store. Pay your way. Buy any 10+ Save 10% - View Offer. com. Requires 25mm Back Box. Select subscribe. Order MK IP66 13A Weatherproof Outdoor Switched Fused Spur &. The essence is that you can actually overload the connection point. Choose from top trade brands. Report your debit card lost or stolen. Sliding Wardrobe Door Tracks Pearwood 2692mm, at Screwfix Direct. 13A max. Step 2 also provides fused protection to the entire outside. Screwfix Community Forum. #89. IP66. #7. 13A max. Satisfied no power, then remove lid on alarm panel. Looking for a IP66 switched FCU to connect a small garden feature into SWA feeding a shed. Home Forums > Screwfix Community Forum > Electricians' Talk > Switch FCU (LED not working) Discussion in 'Electricians' Talk' started by sp383, Nov 13, 2018. Delivery 7 days a weekShaver sockets are allowed in zones 2 + 3 in bathrooms (601-08-01) Yup - proper shaver sockets with an isolation transformer are. An alternative which was suggested was to replace the wall socket with a switch with a flex outlet and wire the multiway into it, via the front flex. Ask a question. Click & Collect. 5 mm. Would it be ok to replace a single socket on ring main with an FCU to run a fridge? jimany, Nov 24, 2023 at 9:02 AM #1 All of the lines and rectangles in RED are the existing 2. Delivered by our approved supplier, Find out more. 60 days free credit available. What is your opinion on this workmanship, I think it is shabby and very unprofessional but the FCU is 2 inches away from the side of the boiler and 15cm horizontally away from the the gas cooker hobs and vertically 40cm high from the cookers hobs. Find out how much the shower pump draws. 60 days free credit available. I think one of the single I currently have though is 47mm, to allow space for the thicker cooker cables. Thousands of customer product reviews. FREE next day delivery available, free collection in 1 minute. 84 Inc Vat. com. Wellwisher, Sep 14, 2023. Get the original bathroom fitters to come and move the fcu. Click & Collect. Even more great benefits of our enhanced digital banking experience: Free: Our mobile app and online banking are always free*. For Appliance Protection Circuits. The red cable is attached to a twin brass connector block with the brown cable from the pendant light. The back wall needs to be as uncluttered as possible. It saves bringing the house lighting circuit outside. 60 days free credit available. For example, with Screwfix Direct Catalogue, you can buy all kinds of high quality building materials, and maintenance and refurbishment items. Free next day delivery available. The FCU is in the middle of the garage (as is the original garage socket it is spurring off) and my new socket powering the LED deck lights is at one end. Home Forums > Screwfix Community Forum > Electricians' Talk > Ip66 FCU. Thousands of customer product reviews. #3. Transfer funds between your accounts. So my plan was to add a fused spur to a ring main, run. Purchase either a 13A standard plug and fit with a 3A fuse and plug in to nearest. Discussion in 'Electricians' Talk' started by Jim, Mar 31, 2005. com, Where the Trade Buys . People’s Trust Federal Credit Union is a member-owned financial cooperative operating from six branch locations throughout the Houston, Texas, area. All BCEFCU branches and the Call Center will be closed on Thursday, November 23 in observance of Thanksgiving. Just a point though when you install the FCU ensure you fit the correct size fuse for the cable, sounds like 0. Then establish if the two cables connected to the FCU's supply terminals are part of a ring final ,or a radial circuit. 5mm cables via wago connectors. 5mm t+e cable to a strip light. 5mm², 2 x 4mm² or 1. 5 T+E thats been spurred directly off the back of another socket and wired to a FCU for a table lamp by the dogs bed in the kitchen, thats. . Terminals accept 3 x 2. L1 is listed in the instructions as the live for the slave luminaire. Socket spur & FCU. com. Free returns. bright_Spark, Mar. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of products. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. UK call centre ready for your call 24/7. 5mm², 2 x 4mm² or 1 x 6mm² cables. 07 Inc Vat. I have a switch in a closet which controls two floodlights outside. Discussion in 'Electricians' Talk' started by MarkN, Nov 1, 2010. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU/Socket Combination. Terminal Capacity. 30 day money back guarantee. £ 24. USF FCU offers helpful services like convenience pay, loan skip-a-pay. Flex Outlet. The FCU is pointless. Would still need a cooker fcu for isolation in the kitchen though. The reason I asked the original question about the second consumer being fed from a 32 amp RCBO, to a 40 amp 30 mA RCD Consumer Unit, with 2X MCB for lights and sockets. So I want to protect the existing socket with a Power Breaker RCD Fused Spur, as sold by Screwfix. Electrican has done the following, but isn't this. Screwfix customers rate this product 4. Home Forums > Screwfix Community Forum > Electricians' Talk > Length of cable from Spur to FCU and then onto appliance. US Main: 724-473-6333. You state, “I have taken taken a spur off a socket on the ring cicuit”. Pay your way. Buy online & collect in hundreds of stores in as little as 1 minute! Free returns. Of Poles Profile Type Switched or Unswitched Sort By: Results per page: 20 MK Logic Plus 13A Switched Fused Spur &. FREE next day delivery available, free collection in 1 minute. The thermal response of a floorslab is much longer than for a radiator system. Is there any reason that this FCU can't be fixed, by a surface mounted box, to the top of the unit instead of cutting a hole in the back of the unit. The fuse in an FCU only protects the load, not the supply, so no issues including it in your ring main. Tiling round FCU's is no different to tiling round sockets above the worktop though. You need sufficient backbox space for 2x 2. 1. 30mA Active RCD. But if you then inserted a 9th socket somewhere in the ring, all of a sudden it would be OK, even though it is blindingly obvious that the mere. Discussion in 'Electricians' Talk' started by Mr I, Feb 8, 2019. FREE next day delivery available, free collection in 1 minute. unphased Screwfix Select. com. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by Product Code Need Help. 5?), and then connect the light with appropriate lighting flex (0. com. Option 2. Drill holes through the back of it through the wall. Check your account balances. Without RCD. dabhand, Jul 24,. Worth mentioning that I've drilled a drain hole in the FCU. You said you are not a spark. Check for dead. Screwfix Community Forum. 2692mm. Sliding Wardrobe Door Tracks Pearwood 2692mm, at Screwfix Direct. Said have not long had bathroom fitted,oh and no evidence of supp. 10x10 — $90 / year. I've heard. Sign in / Register. San Fernando, CA Branch Now Open! Our New California Branch Located at 444 South Brand Blvd. sparky Si-Fi, Feb 23, 2004. Screwfix customers rate this product 4. Maybe read more slowly. Can't see any point in feeding a 13 amp socket through an fcu! Just use 20 amp dp switches. Buy FCU Switches & Sockets at Screwfix. Screwfix customers rate this product 4. com. I now need another socket on the other side of the garage. 99. Free next day delivery available. To start off the new year with a bang, Navy Federal Credit Union introduced five new credit card bonuses on Tuesday. £3. £ 9. PayPal accepted online. Terminal Capacity. Free next day delivery available. ODDJOB, Dec 6, 2010. Headquartered in Gainesville, FL, it has assets in the amount of $315,007,913. To repeat myself for claritys sake: -. Satisfied no power, then remove lid on alarm panel. Screwfix customers rate this product 4. The cable or flex attached to the gas fire is purely to supply the ignition. 14th 14th edition, Jan 19, 2007 #2. 5mm² cables. Get your bills sent directly to Democracy FCU online banking where you can view balances, statement information and pay them all in one convenient place. 9 amps So do you reckon spur off and install fcu. Pay your way. as it's already a spur the socket should be fed through the fcu as well but the problem there would be that as the cooker hood probably only requires a 3 amp fuse you wouldn't be able to draw much. UK call centre ready for your call 24/7. PostHoc, Feb 24, 2021. You can have as many FCU's or sockets as spurs off the ring as their are sockets or FCU's connected directly to the ring. Apple Pay accepted in store. Browse store. Need Help. I know that if on a fcu, you can spur from a spur but I can’t draw more than 13 amps. IP20. Nearest supply was a switched FCU (@3Amp) wired in downstairs ring main for cooker hood. Delivery. Delivery 7 days a week Choose from top trade brands. 2. Afternoon all. 2. Its 28,897 members are served from 9 locations. This, according to the regs, is not allowed. you cannot run spur to spur with sockets incase of over load of cable but. There is a rule saying one spur can only have a single or double socket or FCU though. as per the green lines on the diagram. com. Raised Rounded Profile. 40m/sec Trip Speed. 2. 5mm T/E through the wall to a 13A switched FCU or Timer module. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesTickets are now sold out for Hozier ’s May 21, 2024, performance at the Empower FCU Amphitheater in Syracuse. Me as well, FCU,& feed running up to a 1G unswitched socket. Need Help. Actually they are all correctly called fused connection units (FCUs).