TB-4162 Specifications These specifications apply to the TB-4162 terminal block for use with the PXIe-4162. 10-20-2022 02:07 PM. com. Figure 2. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. the PXIe-4142. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. This document explains how to install, configure, and test the PXIe-4162. Terminal Block, TB-4353, PXIe-4353 PXI Temperature Input Module. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit. Measuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. 0 (最低限) が必要です。Page 3 PXIe-4162 PXIe-4162 Purpose and Introduction This document explains how to install, configure, and test the PXIe-4162. Allow the PXIe-4162/4163 30 minutes to warm up with the PXI chassis fans set to HIGH. National Instruments PXI-8331 User Manual (43 pages) MXI-4 Series Multi-System Extension Interface for PCI, CompactPCI, and PXI Bus Computers. Caution Limit DC power sinking to 12 W. Fast Quotes & Shipping. Some functionality described in I try to measure a single channel voltage and current from my PXIe-4162 SMUs. This file contains installation instructions and compatibility information for Instrument Studio 2022 Q1. 2. Required Equipment for Calibration Required Equipment Recommended Model(s) Parameter Measured Minimum Specifications Two digital multimetersMaster clock source PXIe_CLK1004 Sequencer clock domains One (independent sequencer clock domains on a single instrument not supported) 1 The system channel count is the maximum number of channels available when using multiple PXIe-6570 instruments in a single chassis as a digital subsystem. Read this document and the documents listed in the additional resources section about. NI-DCPower 21. NET Framework 4. 5 n olts) 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m 1 μ 10 μ 100 μ Aperture (Seconds)PXIe-4147. PXIe-4162; PXIe-4163; Behavior Changes. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure UnitIf it is confirmed to be a module issue, follow the steps outlined in DAQ Device or Module Does Not Appear in LabVIEW And/Or MAX. PXIe-8822 728 g (1. * PXIe-4162/4163ソースメジャーユニットはサポートされていません。 † 独立チャンネルではサポートされていません。 Microsoft Visual StudioのサポートPXIe-4145 PXIe-4147 PXIe-4162 PXIe-4163 驱动. Important Notice: Other accessories, manuals, cables, calibration. A red blinking light will generally indicate that the power supply to the chassis is out of spec. You can request. For the PXIe-4141, PXIe-4143, and the PXIe-4145, adding a small resistance in series with each channel can be substituted by instead programming each channel with a small amount of output resistance (0. The PXIe-4162 User Manual provides detailed descriptions of product functionality and step-by-step processes for use. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. But if I try to draw a lower negative current. Adding the. A valid service agreement may be required. The following items are the IDs and titles of a subset of issues fixed in NI-DCPower. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. Return to Home Page; Toggle navigation; Solutions. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。概要. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Power down the computer, then the PXI (e) chassis. NI software installs VC2015 Runtime and . Part Number: 784483-01. Do not exceed the isolation voltage of the instrument. 4. PNG. Remove all the modules and try them one at a time, the LED blinking can be related to a module that is failing. Typically, I would initialize my hardware once. PXI-4132 Current Source and Sink Ranges. Call the self-calibration function. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to connect multiple SMU channels in parallel, so I can increase the available amount of current. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. •Current Range: -50 mA to 50 mA. 62-Pin D-SUB Male to 62-Pin D-SUB Male, 60 VDC, 100 mA, Braided Low-Leakage Cable for SMU—The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). This is not an exhaustive list of issues fixed in the. The SHDB62M-DB62M-LL is a Low Leakage Cable from National Instruments. MLS #. NET Framework 4. NI-DCPower . com. Industries. The PXIe-4162 ships with NI-DCPower driver software, which you can use to program the module. PXIe, 2. PXIe-4162 Purpose and Introduction This document explains how to install, configure, and test the PXIe-4162. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. Specifications Note In this document, the PXIe-4162 (10 pA) and PXIe-4162 (100 pA) are referred to inclusively as the PXIe-4162 . 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Phone: (217) 352-9330. •Source Adapt: Yes. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The 416x have a dedicated analog to digital converter per force and sense pin. Caution Using the NI PXIe-7820R in a manner not described in this document may impair the protection the. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). ground through the shell of the PXIe-4162/4163 front panel connector. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Additional derating applies to sinking power when operating at an ambient temperature of >45 °C. PXIe-4162 configured for normal transient response. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 4162 Roy Pl, Victoria, BC V8Z 7X3 is currently not for sale. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. 5 baths property. D-subminiature connectors are named for the D-shaped shroud present at their mating end and the relatively high interconnect density offered at the time of their introduction. It also features. Buy Source Measurement Units - SMUs. 6 GHz 8-Core PXI Controller The PXIe‑8862 is an Intel Core i7 8‑Core embedded controller for PXI Express systems. Microsoft Visual Studio Support If you are using the NI-DCPower . PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. Voltage Output and Measurement Connecting and Configuring Equipment for Voltage Verification 1. 2 For increased capability, NI recommends installing the PXIe-4163 in a chassis with slot cooling. Looks like now drivers are not available if they. Add. Is it recommended to connect the Source Measure Units in parallel? Solution It is possible to combine two SMU channels in parallel for higher current, however, this may. The PXIe-4162 ships with NI-DCPower driver software, which you can use to program the module. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. It also features. pxie-4162是一款高精度、高密度源测量单元(smu),具有12个相同的smu通道。该模块支持四象限运行,每个通道集成远程(4线)感应功能以实现准确测量,并且运用模数转换器技术,帮助您执行高精度测量。Solution. measurements, as well as analog-to. Manual Trig Routing - SMU-DAQ. 5 digits. The PXIe-4162/4163 SMU differ from other SMUs in architecture. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Please contact Artisan Technology Group Sales for configuration pricing and availability. You can pair the PXIe‑7962 with FlexRIO adapter modules that offer high-performance analog and digital I/O. Measuring Instruments National Instruments PXIe-4162 Getting Started Manual. When attempting to self-test my PXIe-4163 SMU from NI MAX, I see the following error: The self test failed. The information in this document applies to all. It sounds like you can open a session to a device and use it periodically and after some amount of time the session is invalidated. This document explains how to install and use the TB-4162 terminal block with a PXIe-4162. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Measurement Aperture, Nominal 555. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. Return to Home Page; Toggle navigation; Solutions. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Wait two minutes for thermal EMF to stabilize. 1. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog. It also features. The 1,809 Square Feet single family home is a 3 beds, 2. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Use extreme caution when a shock hazard is present. Industries. PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit. CautionThe PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 0 (最低限) が必要です。PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Driver. 0 dropped support for Express VIs in LabVIEW. 2. Kit Contents and Other Equipment. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes an. Specifications are typical at 25 °C unless otherwise noted. Buy 786984-01 - Ni - Screw Terminal Connector Kit, PXIe-4162 SMU. com | PXIe-4162 Specifications PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 5. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 5 baths property. 1 Maximum 480 mA per module. Part Number: 782430-01. Table 1. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. 0 dropped support for Express VIs in LabVIEW. Work with our experts to sustain your critical applications. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. NI-DAQmx. Since I need to simulate the whole serially connected stack of battery cells in a battery module, I would like to connect the SMU-s in series, so each SMU will represent one cell. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. NET Framework 4. 8 PXIe-4162 configured for fast transient response. Microsoft Visual Studio Support If you are using the NI-DCPower . Provides precise voltage or current sourcing and measurement capabilities for PXI systems. Aerospace, Defense, &. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Pin View Pane Drive Section; Pin View Pane Active Load Section; niDigital Configure Termination Mode (VI) NI-Digital Pattern Driver Examples. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. 66 lb) typical PXIe-8862 783 g (1. The PXIe-4147 ships with NI-DCPower driver software, which you can use to program the module. Initialize with channel -> configure -> initialize -> measure -> close. Touch any metal part of the chassis to discharge static electricity. Contact Us for Immediate Support or Read More. Refer to the NI website for an up-to-date list of known issues in NI-DCPower 18. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 3 PXIe-4162/4163ソースメジャーユニットはサポートされていません。. 5 mA to 24 mA for I OL and -1. NETクラスライブラリを使用している場合、. Please refer NI's whitepaper on merging SMU channels. PXIe-4162 / 785680-01 - NI. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. PXIe, 40 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. This allows the SMU to have high impedance between pins thus Force and Sense do not have a. PXIe-5160/5162 Front Panels CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 TRIG CLK IN PFI 0 OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 CH 2 CLK IN OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 3 Note PXIe-5160 shown. Re: PXIe-4163 running voltage sequence occur "Internal Hardware Error". Does PXIe-4162 and PXIe-4163 SMUs supports both Current and Voltage cascading similar to the other SMUs? Rgrds. Return to Home Page; Toggle navigation; Solutions. . 3 PXIe-4162/4163ソースメジャーユニットはサポートされていません。. 3 No support for PXIe-4162/4163 source measure units. 5 mA to -24 mA for I OH. It includes the Digital Pattern Editor for configuring pin maps, specifications, levels, timing, and patterns. PXIe-4162 does not meet the Maximum source update rate spec of 100000 S/s. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Added support for the PXIe-5110, PXIe-5111, and PXIe-5113 oscilloscopes, newly supported in NI-SCOPE 18. 1. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. The PXIe-7862 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals for complete flexibility of timing and synchronization. 4. A valid service agreement may be required. single-family home is a 4 bed, 3. 5 n olts) 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m 1 μ 10 μ 100 μ Aperture (Seconds) Re: PXIe-4162 Cannot Reset. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 00 lb) typical. You can access the software and documentation known issues list online. dubatov. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. National Instruments PXIe-4162 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 12 Voltage Range: -24 V to 24 V Current Range: -100 mA to 100 mA Current Sesitivity: 100 pA Source Adapt: Yes Part Number: 785680-01Please contact Artisan Technology Group Sales for configuration pricingPXIe-4162: 786984-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a: PXIe-4163: 786985-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a *Triaxial cables are compatible with the PXIe-4138/4139 if using the SA-413T adapter. Industries. Return to Home Page; Toggle navigation; Solutions. The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. SPECIFICATIONS PXIe-4162 PXIe, 12-Channel, ±24 V, 100 mA Precision PXI Source Measure Unit Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high-speed acquisitions up to 100 kS/s per. Windows Server 2016 64-bit. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. October 2024 376739C-01 Calibration Procedure PXIe-4162/4163 Calibration Procedure The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. I am opening a ticket. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis Figure 2. Before you begin, install and configure your chassis and controller. 0 (minimum) is required. It is possible that we stressed some circuits, but I think we did not. Resistance Specifications Accuracy All resistance accuracy specifications apply to apertures of ≥100 ms, with Offset Compensated Ohms (for ranges ≤10 kΩ) or Auto Zero (for ranges ≥ 100 kΩ) and ADC calibration enabled. Industries. This documents provides information on calibration service levels available for NI Products. 0. This is not an exhaustive list of issues fixed in the. Industries. If you have an issue ID, you can search this list to validate that the issue has been fixed. element14 India offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. ground through the shell of the PXIe-4162/4163 front panel connector. Part Number: 783762-01. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162; PXIe-4163; LabVIEW NXG Help. PXIe, 24-Channel, ±24 V, Precision PXI Source Measure Unit. You can. 1. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. pxie, 12 通道, ±24 v, 精密 pxi 源 测量 单元. Also for: Pxie-4082, Pxie-4081. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. This home was built in 1994 and last sold on. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Brand: National Instruments | Category: Recording Equipment | Size: 0. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). The PXIe-4162 and PXIe-4163 extend this to 204 and 408 channels, respectively. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. PXIE-4162 CURRENT AND OPEN-SENSE PROTECTION ACCESSORY. Channels are isolated from each other and from chassis ground. •Current Sesitivity: 10 pA. GETTING STARTED GUIDE. 2 For increased capability, NI recommends installing the PXIe-4162 in a. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162 PXIe, 12-Channel, ±24 V, 100 pA Precision PXI Source Measure Unit Read this document and the documents listed in the additional resources section about installation,. NETクラスライブラリを使用している場合、. This is to help prevent the SMU from damaging a DUT if the sense leads do become disconnected. 5 has the following requirements: Processor—2. Table 1. Ensure that the ejector handle is in the downward (unlatched) position. You use the PXIe‑8862 for processor-intensive RF, modular instrumentation, and data acquisition applications. The following list details the hardware models supported in NI-DCPower 17. This file contains installation instructions and compatibility information for Instrument Studio 2022 Q3. procedures for the PXIe-4162/4163. Email: info@artisantg. Complies with the essential requirements of the following applicable UK Regulations: Electromagnetic Compatibility (EMC) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic. Pxie, 12-channel, 24 v, 100 ma pxi source measure unit (20 pages) Measuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments NI PXIe-4139 Calibration Procedure. Configuration: •Number of SMU Channels: 4. The following diagram shows a cross-section of the SHDB62M-DB62M-LL when used with a PXIe-4162. Microsoft Visual Studioのサポート. It helps simplify the task of designing automated test systems for a wide range of applications—from aerospace. The PXIe‑4112 is a programmable DC power supply with isolated outputs. NI‑DCPower 19. 4 V peak, or 60 VDC. Table 1. PXIe-4162; PXIe-4163; Behavior Changes. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Disconnect or disable all connections to the PXIe-4162/4163. This document explains how to install, configure, and test the PXIe-4163. View context help in LabVIEW by pressing <Ctrl-H> and hovering over an object. You can merge multiple 4162 channels for increasing the current capability. The TB-4162 terminal block is used for screw terminal connections with the PXIe-4162 SMU. 次の表および図は、PXIe-4162の電圧および電流ソースとシンクのレンジを示します。 表 1. If the issue persists after these steps. 6 GHz 8-Core PXI Controller The PXIe‑8862 is an Intel Core i7 8‑Core embedded controller for PXI Express systems. If you have an issue ID, you can search this list to validate that the issue has been fixed. Return to Home Page; Toggle navigation; Solutions. 10 20 Hz to 20 MHz bandwidth. PXIe-4162/PXIe-4163 SMU Open Sense Resistor AccessoryScrew Terminal Block for the PXIe-4162. Installing the TB-4162. Windows 10 64-bit. Brand: National. Return to Home Page; Toggle navigation; Solutions. Optional Items. Note Before you begin, install and configure your chassis and controller. Supported Hardware. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. NI-VISA. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. It sounds like you can open a session to a device and use it periodically. used. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Verifying the System Requirements PXIe-4112. ships with NI-DCPower driver software, which you can use to program the module. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. Table of Contents. measurements, as well as analog-to. •Current Sesitivity: 100 pA. Back to top. 53 GHz Intel Core 2 Duo processor or equivalent. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. ft. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. Buy PXI Source Measure Units & Bundles. Calibration could fail for the following reasons: 1. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. The PXIe-4163. Refer the NI DC Power Supplies and SMUs Help for more information about. Bug Fixes. Table 1. Support for new variants of PXIe-4162, PXIe-4163 (10 pAsensitivity) Completed Support for new variant of PXIe-4190 (500 kHz stimulus) Completed User Experience Improvements Undo/redo functionality for panel properties Localization Launch plugins from command line Completed Advanced Capabilities Remote Instrument Access for supported RF Instrumentspxie-4144 pxie-4145 pxie-4162 pxie-4163 문의사항 여러 개의 smu를 사용하여 직렬로 연결된 배터리 셀을 시뮬레이션하고 싶습니다. You use the PXIe‑8862 for processor-intensive RF, modular instrumentation, and data acquisition applications. NI-DCPower 21. The PXIe-4162 ships with NI-DCPower driver. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. NI-488. PXIe-4162; PXIe-4163; Behavior Changes. PXIe, 24-Channel, ±24 V, Precision PXI Source Measure Unit. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 82. This. Looking for something else? For information not found in the User Manual for your product, like specifications or API reference, browse Related Information. The following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. OCP is triggered when a fault condition occurs that would otherwise cause the device to sink or source current beyond its specifications for an excessive amount of time. Indoor use only. This cable is insulated by. Even when following the above recommendations, combining channels can still present issues with noise, stability, and outputting the proper voltage/current. The PXIe‑6570 also includes debugging tools like Shmoo, digital scope, and viewers for history RAM, pin states, and system status. •Current Sesitivity: 10 fA. GETTING STARTED GUIDE PXIe-4147 PXIe, 4-channel ±8 V, 3 A PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4147. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. •Current Sesitivity: 100 pA. •Current Range: -100 mA to 100 mA. NI-488. NI-DCPower 21. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. Industries. NI-DCPower 17. The SHDB62M-BW-LL features two conductors that are twisted and encapsulated within. 8 PXIe-4162 configured for fast transient response. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes examples. Microsoft Visual Studioのサポート. I'm trying to setup a PXIe-4162 to draw -50 uA from a chip, but regardless of the settings I use, the SMU is sinking -130 uA. Wait two minutes for thermal EMF to stabilize. PXIe-4163 Purpose and Introduction. . Windows Embedded Standard 7 (SP1) Windows Server 2008 R2 (SP1) 64-bit. NI-DCPower 20. The PXIe-4162 (Part Number: 785680-01) is a unit of estimation of high-density source (SMU)-the device is equipped with 12 SMU channels. The following items are the IDs and titles of a subset of issues fixed in NI-DCPower. •Current Range: -150 mA to 150 mA. 7. Minimum order of 1 items Multiples of 1 only Please enter a valid quantity. Products in. NET Class Library, the . NETクラスライブラリを使用している場合、. Disconnect or disable all connections to the PXIe-4162/4163. Verifying the System RequirementsPXIe-4112. 2. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Figure 2. 8 MS/s 100 kS/s Max Update 100 kS/s Max Voltage 10 V 24 V 6 V 8 V 24 V 24 V Max DC Current 100 mA 150 mA 500 mA 3 A 100 mA 50 mA Current Sensitivity 100pA/10pA 100pA/10pA 150pA/15pA 100 fA 10pA/100pA. PXIe-4163 Purpose and Introduction. Getting Started with the TB-4162. It sounds like it's an NI branded controller and chassis. 6: To support independent channels, numerous NI-DCPower functions have been superseded by new versions that can access instrument channels independently. You can request. Industries. Looking for something else? For. PXIe-4144; PXIe-4145; NI 416x SMUs. Figure 1. Caution Shock hazards exist when voltage levels are greater than 30 VRMS, 42. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. You can. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). NI‑DCPower 19. Manuals. See all Driver Software Downloads. 배터리 모듈에서 직렬로 연결된 전체 배터리 셀 스택을 시뮬레이션해야하므로 각 smu는 하나의 셀을 나타내도록 smu를 직렬로 연결하고.