Ralms @fcwilt 8 Aug 2020, 08:57. g. yello3d. The 3D models contain files for a mechanical gripper that attaches to the print head of the printer and can move chess pieces around. G4 S1 ; wait for one second. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. yello3d. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. 455513e-8My printer has sat for a couple of months because well, moving. 9 ;extrude 0. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. Make sure you clean out the heatblock and refit the nozzle properly, hot tightening it, etc. Step 6. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. wordpress. . 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. G1 E15 F500 ; load filament insi de the gears. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. 5. g: T0 ; select tool 0. @oracledude said in Extrusion Control in DWC unavailable, even after M302 P1: Your tool definition misses a D parameter for the extruder drive. droftarts administrators @flyscha last edited by . Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". Reply Quote. Reply Quote. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. the X motor. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. Users of single-extruder machines often put a T0 command at the end of config. is not colored in WebControl as in the example screenshots i saw. Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. @fcwilt said in Duet 3 Extruder control disabled: Just to be sure turn the bed heat on along with the extruder heat and see if that changes anything. Users of single-extruder machines often put a T0 command at the end of config. M302 P1 ; enable cold extrusion. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:M581 P1 T2 S0 R0 ;define trigger for filament auto load triggers trigger2. I would be very gratefull for any help. the ONLY command that should spin a motor before the printer homes is G28. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 3V is removed from the E1STOP signal, in which case the log will display the command entered. Send M302 P1 to allow Cold extrusion; Send M600 T1 to initiate Filament swap; Follow the Instructions on the Screen. oracledude 5 Dec 2021, 21:47. . 0024. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. org ] Reply Quote. Large delta printer [ miscsolutions. g ; go to purge bucket. the X motor. I can't help you with fans on RADDS, but "Attempting to extrude with no tool selected" means just that. send T0), and enable cold extrusion with M302 P1. 0. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. one immediately before X). I copied the first 2 layer g-code here, and I would like to know if anyone have an idea to solve this issue. 0. 36°C/sec measured -0. Reply Quote. Summit Racing Part Number: FMS-M-6701-B302. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. M808 L. However, some firmware distributions might explicitly prevent these two commands of turning off the check. To test for this, with the power off swap the E0 connector on the Duet with another one e. droftarts administrators @flyscha last edited by . May 04, 2017 11:25PM. GCode and RepRapFirmware. Heating Bed manually by G-Code. good evening . M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. 8Hz when using P4. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPM302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. M302 P1;G92 E0. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. Send T0 in the gcode console and check the buttons again. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. g. 0 Y0. wordpress. If you are using the web interface, go to the Gcode. . This will hopefully make it a bit easier for me to. @Phaedrux @dc42 @T3P3Tony. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. Other possible causes are a bad stepper motor or cable. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. . 7. droftarts administrators @flyscha last edited by . M302 P0 S170. one immediately before X). G11: Unretract Used while Firmware retraction is configured in your slicer, along G10@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0CDoes the interface not respect M302? Hi! Can't figure out how to turn the e axis using the lcd knob while the extruder is cold. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. Other possible causes are a bad stepper motor or cable. These are commands that one may enter into the OctoPrint terminal tab. extrusion temperature 160. Other possible causes are a bad stepper motor or cable. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. This document describes the commands that Klipper supports. (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. Usage. To test for this, with the power off swap the E0 connector on the Duet with another one e. R"Filament out" S2 ; Step 3 > After checking you click okay and it starts reversing filament M302 P1 ; Allow cold extrusion G1 E-520 F3000 ; Unwind the filament 400mm ; Step 4 > Notify user and offer option to place new filament M291 P"Remove remaining filament, insert new filament and continue" R"Insert new filament" S2 G1 E480 F2000 ; Load. g. Re-enable with. The code sends commands to an Octoprint instance. 0 goes forwards M584 X0. Your config files updated for bugfix Configuration. microswitch) endstop. @jens55 you are right dude I had missing to remplace one "S" argument by "H" in homez. @deckingman please find ;Cold extrusion M302 P1 ; allow cold extrusion ; Drives M569 P0 S1 ; physical drive 0 goes forwards M569 P1 S1 ; physical drive 1 goes forwards M569 P2 S1. TfreeN. Sending T0 initiates the heater and then faults out. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. 0 C199. 4. Crypto@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsExtruder SKR2 not spinning. Then. First print: tiny layer shift at layer 6. M302_P1_COLD_E. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?M302 P1 ; cold extrude. G-Codes¶. : till no luck with Extrusion Control jogging buttons. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. I cannot get the extruder controls to show up in the web interface - it is greyed out. M302 P1 ; Allow cold extrusion M82 ; use absolute distances for extrusion G92 E0 ; Reset Extruder G1 E-430 F3600 ; retract 430 mm M302 P0 ; Disable cold extrusion T-1 P0 ; Deselect all tools without running any tool change macros. I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. Not sure what could be wrong in your case as M302 with no parameters should report the current cold extrusion protection settings. . I just wondered if there was a way of "embedding" it in the config files so that it runs by default. Large delta printer [ miscsolutions. G92 E0 ;zero the extruded length again. droftarts administrators @flyscha last edited by . M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. what gcode do i need to send… Premium ExploreTo install this plugin, open DWC, go to Settings -> Plugins -> External Plugins and click on "Install Plugin". 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPThermostatic control is turned on. So when i home it, x and y go to 225 and z goes to 0. Expected behavior: The Unload should ignore the temperature on the Hotend and do its. In the E0 port of the board, I didn't see the red led is on after I plug the motor. Send T0 before you try to extrude. g ; Unload to above y-splitter. +Z should move the bed down. After replacing PCB managed to get everything up and running. 1 Reply Last reply Reply Quote 0. So currently I've been slowly working my way throw learning Marlin and Visual studio as well as trying to build my 3d printer with the SKR2. 1 Reply Last reply Reply Quote 0. M302 S160 ; lower cold extrusion limit to 160C {if filament_type[initial_tool]=="FLEX"}G1 E-4 F2400 ; retraction{else}G1 E-2 F2400 ; retraction{endif}. G1 F900 ; set the feed-rate // Starting the print with Layer 0 ;Layer count: 2. oracledude 5 Dec 2021, 21:47. Here is a handy list of g-code commands [ reprap. Put this as first line of your custom gcode. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?M302 P1; Allow cold extrude : T0; select tool 0: G10 P0 S180; heat tool 0 to 180 and wait: M116 P0: G10 P0 S120; cool tool 0 to 120 and wait: M116 P0: G1 E-20 F300; retract 20mm at 5mm/sec; change the following E values to suit your Bowden Tube length : G1 E-50 F600; retract another 50mm at 10mm/sec: G1 E-200 F3000; retract another 150mm at. The macro folder can divided into sub directories to more easily organise your macros by type. g. Extrude a small amount to ensure that your extruder motor is on and holding. 0. M116 P0 ; wait for heating up. It should be possible to make a Gcode file in a text. 16 07:24. microswitch) endstop. . Don't forget to send M302 P0 later to restore normal safety. Duet 3 mini 5+ installed in a Sidewinder x1 v1. The printer functions and works as a normal syringe printer and is compatible with the Lulzbot Cura slicer software. Now with Marilin 2. Large delta printer [miscsolutions. Good morning. The extruder motor turns but it won't really push the filaments to get extruded. com ], E3D tool changer, Robotdigg SCARA printer, Crane. Only users with topic management privileges can see it. : Heater 1 fault: temperature rising too slowly: expected 2. Heater 1 fault: temperature rising too slowly: expected 2. Last edit at 01/11/2023 01:58AM by Dust. G1 F200 E0. 8 is far too low for two reasons: 1. Re: How can I move E steppers? January 11, 2023 02:36AMSo are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. @patel said in how to change homing sequence: M3D promega There's a full guide to this on M3D's Promega support pages. I used to use "Pronterface" for that. Home page Shop all products. After replacing PCB managed to get everything up and running. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. @Phaedrux said in Extruder motor not working. droftarts administrators @flyscha last edited by . Only users with topic management privileges can see it. 042". 16AFDVC1 -. Then reduce the distance, and stop just before the filament disappears into the hot end. M302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. @Phaedrux said in Extruder motor not working. You want to leave that in case the bed or anything else still has a heater, and it wouldn't fix your problem anyway. The prototype was outsourced to Oshpark. A well-grippable 3d-printable chess set is also included. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. 1 Reply Last reply Reply Quote 0. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Then select the plugin ZIP file and confirm the following steps. In order to report the current status, run. 4 card. . droftarts administrators @flyscha last edited by . 2nd print: 10seconds permanent skipping at 10x30 at layer 18mm. EDIT: OK, so you're using RRF 3. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Hello. Serial No. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. 43 M562 Reset Temperature Fault [Pnn] Reset temp fault on all heaters or on heater Pnn M562. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). 3 mm and released @ about 0. 3 ; Filter. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. In order to report the current status, run. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysG-code for the 4th axis of the tangential knife after a slight modification {ASCI "conversion " (" to ";" and "A" to "E") allows you to run the code in the Marlin software. Type M301, M302 System Analysis and Measurement Centre M301, M302 System Analysis and Measurement Centre Service Manual. zip. There is no minimum steps/mm set in the firmware. Re-enable with. Sometimes it moves once but doesn't execute the other commands. This manual can be used as an EIA/ISO programming manual. Heaters, 24v 40W - Im using 24V 400watts power supply. g. g. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. 7mm, the output contact is engaged @ about 0. 86272-ad-b. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. retraction temperature 90. and forward - so we have are at the point we wanted to be without. Now with Marilin 2. 7. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . Repetier 1. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . @dc42 That doesn't seem to work. Send G1 E100 F200 to extrude 100mm of filament. ; Configuration file for Duet WiFi (firmware version 2. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. 0C. I've now managed to calibrate my Steps/mm of the extruder by manually issuing G1 commands. Expected behavior: The Unload should ignore the temperature on the Hotend and do its thing. 2 Firmware:3. Volume 2. Command "M302 P1" works properly. 2 Y0. However, Slic3r inserts this code after the first Z-lift which is befo. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Green - filament present. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. The M2 Carbine rifle is a fully automatic version of the M1A1. Thanks. When tfreeN is called, filament is retracted above the y-splitter. For firmware versions 1. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. 5 and 1. Hi there, Doesn't make a diference. This was done on Marlin 2. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. M302. 5 fans I have it doing all zeroing and even bed tramming! Awesome to see it tram a skewed-. Business, Economics, and Finance. Features solid metallic core with. gcode" and run that from an SD card. Description The M2 Carbine is. 06. Cannot get extruder motor to respond. Other possible causes are a bad stepper motor or cable. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. 1 Reply Last reply Reply Quote 0. Set the temperature (and enable) using. Macros also allow for naming gcodes with easier to remember names. It's simple. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. 155 5. The extruder port might not actually be dead - Marlin has an idiotic function turned on by default that prevents extruder movement if the hotend is not up to temperature. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Send T0 in the gcode console and check the buttons again. 4. M122 shows some weird messages: Driver 0: position 38683, standstill, read errors 0, write errors 1, ifcnt 23, reads 6775, writes 6, timeouts 0, DMA errors 0 Driver 1: position 38683, standstill, read errors. The extruder can't always move as fast s the other axes, that's why my examples to move E use a slower speed (F value). 5. If that's not the case, we need to change the direction of rotation. What could be the causeMarlin defaults to "no cold extrusion". Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 0. g at here G91 ; relative positioning G1 Z5 F6000 S2 <--(problem is here, remplace S2 by H2) ; lift Z relative to current position G90. M302 P1 ; allow cold extrusion. 0. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Send T0 in the gcode console and check the buttons again. G1 E200 F500 ; extrude 200mm, you may need to reduce speed for very soft TPU. retraction temperature 90. CryptoAs well as selecting the tool with e. M302. I would be very gratefull for any help. However, I can't get the servo running with the new firmware. @agent0810 said in Homing advice: i was able to. It has a different internal construction. 2 ; interpolate mbl probesG29 P3. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. plan view. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. 9 Windows 10 I am using a macro in reprapFirmware to pause the print for a certain length of time after evey layer. M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to. The home position is detected by the punch slide HP sensor (PS302). This is by far the only way I am able to see that the steppers can actually work through the board. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. Slic3r 1. M569 P1. Page 28 2. Large delta printer [miscsolutions. Here is my diagnostic file and my config. 3 ; Filter fan. M302 P0. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. To test for this, with the power off swap the E0 connector on the Duet with another one e. 0. I used to use "Pronterface" for that. M302 P0. I have to turn the power off and on to reset it. Click to Enlarge. 0. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. My pause button in webcontrol stopped working - it's ghosted with a stop-sign courser when I hover it. This topic has been deleted. 16 and earlier, set the B parameter (beta value) to 4388. 8 is far too low for two reasons: 1. It works perfectly fine on RRF2 though. e. I'm not sure if this gets cancelled at power off. Deactivate with "M106 P1 H-1". Crypto‘M302 P1 ; disable cold extrusion checking’ 2. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. I'm at a dead end where I can't seem to get the E0 Stepper motor to. M302 P1 ; allow cold extrusion. This topic has been deleted. . I can get the x,y,and z motors moving in pronterface, but the extruder…@jfavre said in Extruder motor not working. And now even Col Extrusion M302 P1 is generating errors. 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. 3 (3. 8 on Thu Feb 20 2020 13:12:07 GMT+0100 (centraleuropeisk normaltid) ; General preferences G90 ; send absolute coordinates. . Grabbed a Ramps 1. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. UPC: 756122055144. Set the temperature (and enable) using. Hi all, Can anyone help using DC42 firmware I cannot get the extruder to cold extrude even when using the M302 P[1/0] to enable or disable the prevention. Without inserting the wire I tried to make a print and the extruder works. -> no reaction at all - even after "M302 P1" What is working: Homing. +Z should move the bed down. Upon installation, you can see a new Revo directory in the Macros list which contains the following items:. g. CryptoM302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears. On the X and Y we are using iHSS57-36-10 closed loop.