All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. com. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. 3 (damper installed with duct upstream and downstream). This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Commercial Dampers. Axles that positively lock to blades without screws or welds. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. Phone. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. When equipped with blade seals, provides positive shut-off. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. It is recommended for heavy duty applications using multi-section dampers where either unison or sequence operation is required. 6 psi to 44. Rectangular Silencers. 5. Louver blades are . The. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. Dampers shall be in all respects equivalent to Ruskin Model CD35. Haldeman is a stocking Manufacturer Representative and Distributor of HVAC products since 1933. Example: Maximum design total pressure of 8. Zone Control. The FSDR60 is the ideal choice when round duct is used on a project. ft. Stops the leakage of smoke in static and dynamic smoke systems. Consult Ruskin or your Ruskin representative when damper is to be. 3. Select from manual cable drive control to fully automated pressure depended and pressure independent. Dampers shall be Ruskin Swartwout Series Model CBDR912. The Ruskin® Portfolio of life safety solutions offers more than 70 models of 1½ hour rated fire dampers and combination fire/smoke dampers that can be used with. Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. 6) 304tested and classified Ceiling Dampers (also called Ceiling Fire Dampers or Radiation Dampers) to provide fire and heat protection where HVAC components penetrate the ceiling membrane. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. • Airfoil blade design for low pressure drop and reduced noise generation. Static pressure and CFM are corrected to. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Do not weld or fasten angles together at cor-ners of dampers. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476 Document Title O & M for Commercial Control Dampers Limited Warranty Document LINKS TO IMPORTANT. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. Masonry/Wall or Floor: #10 self-tapping concrete screws. FILES (0) Share this page:Energy Recovery Ventilators. g. Rectangular Silencers. Enter the Pressure Drop Chart at the determined area factor. Static only damper labels are not permissible. Axles that positively lock to blades without screws or welds. ft. Ruskin provides perfect control Fire Smoke Dampers. The commercial dampers provide low pressure openings with exceptional pressure drop performance, while the industrial line includes heavier gauge materials to. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. emergency, dampers and their actuators alike may be required to operate at elevated temperatures. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. 1. Use "Mount With Arrow Up" label as a guide for proper damper orientation. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. Maximum velocity for V-Groove blade 2000 FPM and Airfoil blades 3000 FPM. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. g. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. MODEL CBDR912 FIBERGLASS ROUND BACKDRAFT DAMPER 3900 Dr. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. Linkage is concealed in the frame out of the airstream for low maintenance and reduced. 5Hr » Combination Fire/Smoke Dampers 3Hr » Smoke Dampers » Corridor Dampers » 1. 5 illustrates a plenum mounted damper. Ruskin furnishes, installs, and factory commissions actuators from a diverse lineup of manufacturers offering 2-position, 3-position, or modulating control. The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. It features: Maximum velocity of 4,000 fpm. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. 7476 Fax: 816. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Louver and Architectural Solutions. Autodesk®Revit® is Building Information Modeling (BIM) at its best. Dampers shall be in all respects equivalent to Ruskin model IL35. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. Standard features vary by model to make application selection straightforward. Providing accurate control or isolation of. Damper – Ruskin fire or fire/leakage rated damper in minimum 20 gage (1. Face and by-pass. It locks together without bolts, screws, or rivets that could shake loose. Life Safety Dampers. For up-to-date information visit CFD . Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. In addition, the DC models have. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. Products include differential pressure probes for high velocity applications, combination units that measure and maintain flow, and highly sophisticated, intelligent solutions that incorporate thermal dispersion technology with microprocessor based. lbs. w. 25" w. Ruskin FAST and PFMA are 20 guage steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. Unlike conventional mounting angles that cannot be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: One piece angles (fastened together in the corners). The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin Literature. Following system stabilization, normal counter-balance operation will continue. Ruskin Literature. • Ruskin frame-mounted actuator bracket to simplify field installation of most actuators (specify actuator and action, i. Model ‘G’ curtain fire dampers are offset. Ruskin was founded in the Ruskin Heights area of Kansas City in 1958. Enter your email and join our mailing listDesigned for isolation and containment of the airstream, Ruskin bubble tight industrial dampers for round or rectangular air paths will meet or exceed bubble tight leakage requirements in conformance with AMCA Standard 500D and are available with factory-supplied and mounted actuation. The CD51 is structurally designed for velocities to 2000 fpm. 5 Hour. Ruskin’s Information is not a. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. All calculations are with external mounted actuators and accessories. The CD80AF2 Industrial Control damper has an 8" frame. • Airfoil High Performance Dampers • Triple-V Standard Performance Dampers • Ruskin Exclusive True Round Dampers • Ruskin Fast Mounting Angles • Complete Corridor. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. 3 (damper installed with duct upstream and downstream). 24VAC modulating actuators (spring return or fail-in-place) can. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. GRANDVIEW, Mo. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. Maximum 8" static pressure. Availability: Get a Quote. per sq. The Damper part prices in this catalog do include freight within the contiguous 48 states. The CD82HT Industrial Control Damper has an 8" frame. Damper size shall not exceed 90" x 48" (2286 x 1219) or 48" x 90" (1219 x 2286). GENERAL INSTALLATION NOTES 1. 6 Pneumatic Damper Actuator is recommended for control of outdoor, return air, exhaust, face and bypass, and fan discharge dampers. The foregoing limited warranty does not apply to (i) consumable products and components (e. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. FSD35. Airfoil blades, which. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. Dampers shall be in all respects equivalent to Ruskin Model CD40. Non-stick, noncorrosive bearings that assure. Noise Control. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Standard damper assemblies are furnished ¼” smaller. Ruskin Literature. Determine area factor for damper by entering the Area Factor Table through duct width and height. Ruskin’s optional wireless damper Inspector™ , utilizing wireless communication protocol by EnOcean®, is the ideal solution for mandatory testing of motorized life safety dampers per NFPA* and Building Code requirements. • Fire smoke dampers larger than single section may require multiple actuators. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Dampers above 18" (457) – 10 gage steel (3. Noise Control. When used in fan discharge applications, damper should be the damper frame. Multi-section dampers typically use jackshafts to link sections together. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. To meet the diversity of fire and smoke protection requirements,. 3. g. The ARD25 is. of damper with minimum of 20 in. Commercial Control Dampers; Sound Control; Industrial Control Dampers; Software. A. See “Combination Fire Smoke Damper Multiple Section Detail” spec Ruskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. Figure 5. g. Issue ‘E’ Fuse Link 4. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. Industrial FAQs. Torque applied holding damper closed at 10 in. Axles shall be square or hexagonal positively locked into the damper blade. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. 552. We always proudly labeled our literature with the AMCA Certified Ratings Logo and now we will be labeling on dampers as well. (2 kPa). 8) galvanized steel struc-Products. Ruskin Brands and Locations. Ruskin offers threeII-G-Angle-514/Replaces II-IBD Style G -109 ©Ruskin 2014 DYNAMIC FIRE DAMPERS See label on damper for maximum air flow and pressure. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. a. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. Automatic Balancing Dampers. 00. Specifier Select Option Dampers shall be equipped with factory installed damper. For proper operation, damper must be installed square and free from racking. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Every damper is built with performance in mind and tested per AMCA standards. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). • Airfoil blade design for low pressure drop and reduced noise generation. D-DIA. Stainless Steel V-Groove Blades. The damper shall be rated for dynamic closure at 2000 fpm (10. dampers. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. UL approval for dual directional air flow. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Dampers furnished actual size. Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. ft. STATIC PRESSURE IN IN. , Ltd. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). g. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power The EFL or PFL heat-actuated release devices permit controlled. Certain actuators in Table 1 are UL Recognized Components under. Industrial Fiberglass Louvers. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Commercial Dampers. b. Offset single blade design lets Ruskin engineers calibrate the damper operation to exact customer specification. See “Smoke Damper Multiple Section Detail” spec sheet for details. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. ) SUGGESTED SPECIFICATION STATIC PRESSURE (Inches Water Gage) AIR FLOW IN C. angles together at corners of dampers. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. CD60 | Galv. SP100: Dampers shall be equipped with factory installed damper position indication switch package. Ruskin fire/smoke dampers. (2) ‘E’ Clips 3. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. It features: Corrosion resistant backdraft protection from its stainless steel construction. Opposed blade dampers must be operated from a power blade on the. Inspiring the industry with thought provoking, revolutionary ideas, Ruskin airfoil blade dampers comprise the only damper design incorporating a single piece roll-formed frame and blade. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. g. Damper shall be Ruskin model PVC12. Quick Select. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. 0) sleeve. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. Out of wall “OW” fire dampers are designed so that the leading edge of the damper frame can be up to 8" (203) out of the wall, partition or masonry floor. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERS Catalog. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood Factory or field supplied plenums Assembly designed to accept grilles with up to 2 1/2" grille depth with OBD Through ceiling. Sun Control Sunshades. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. 075 lb/cu ft air. Ruskin offers blast suppression dampers which are custom designed to each application. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. For some applications, it is essential that thermal conductivity be kept at a minimum. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec-ommended maximums. Models CD36, CD35, IL35, CD40 and CD403, 4". It features: Galvanized steel construction. ft. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. Auto-Balancing. • Fire smoke dampers larger than single section may require multiple actuators. Speak With a Technical Expert. 5 Hour for use in 2 Hour Walls. Noise Control. Ruskin fire dampers may be installed using Ruskin PFMA. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. Torque applied holding damper closed at 10 in. static pressure. com . Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Find the pressure drop across a 18" wide x 18" (457 x 457) high Model CD80AF4 control damper. See “Combination Fire Smoke Damper Multiple Section Detail” specRuskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. It features: 1-1/2 hour rating. Louvers & Architectural. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Pressure drop and free area may vary. Note: Multiple section dampers are not intended to be structural supports. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. lbs. It also features: Frame corners that are internally braced to reduce racking. II. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. > Case Studies. Unlike other ceiling. 025” thick formed aluminum with concealed blade linkage, synthetic bearings. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. - Damper/sleeve assembly furnished actual size to inside of sleeve. Dampers may tolerate higher pressures and velocities than those listed here. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Damper Dia. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. CDR25 and CDO25 dampers are round and oval volume control dampers. Airfoil blades, which have greater strength, less static pressure, superior sealing. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. The CD40x2 has an 8" frame and aluminum construction. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. 2. FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. upstream of the damper. It features: AMCA Class 1A leakage for energy savings R value – 2. Greaves Rd. It is also: Flange mounted. 500. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. Pressure limitations shown above allow maximum blade deflection of 1/180 of span on 60" (1524) damper widths. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. g. HVAC For more than 60 years, Ruskin has been the leader in developing innovative solutions for the HVAC industry. 1/4” cfm at 4” w. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. 2. Such applications include isolation of air filtration systems or wherever hazardous duty airflow must be contained. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Horizontal mount dampers may be installed with the jackshaft above or below the floor. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Dampers shall be in all respects equivalent to Ruskin Model CD40. a. damper section width as indicated. a. 4 psi respectively. Backdraft blades are . g. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/ Steel Stud Wall. back pressure depending on damper size. Backdraft blades are . per sq. Consult Ruskin on your Ruskin representative when a damper is to be applied in conditions exceeding recommend-ed maximums. ©Ruskin 2000 3900 Dr. Hours: 9am - 5pm CDT M-F. After 15 minutes, the damper is closed and reopened. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Product• Ruskin FAST Angles • One piece angle shipped with the damper • Available in 1-½" or 2-½" • Metal, wood and masonry walls/floors • Permits damper installation before or after drywall installation • Approved for all Ruskin fire, smoke and fire/smoke dampers LaBOr Saver #2 IntegraL and factOry SLeeveSRuskin® has the largest selections of AMCA certified dampers in the industry. These fire dampers are used for the protection of openings in walls, partitions, or masonry floorsDamper Dia. 11-17-20. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. g. Control dampers shall be produced in an ISO9001 certified factory. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. The TS150 must be installed at the factory and cannot be added in the field. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. The CD51 Control Damper has a 5" frame. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Ruskin's Insulating Control Dampers are perfect for performing this task. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. Damper Maximum Size Velocity (FPM) Pressure (in. Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 Dr. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. OPTIONS True Round Fire Damper See model FDR25. g. It features: A static pressure control option, which enables field adjustment to maintain static pressures ranging up to . g. consider an airfoil blade damper, such as Ruskin model CD60. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERSLeading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. g. Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. and a maximum of 3 CFM sq. Commercial Control Damper CD60. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. 7476 Fax: 816. Designed for isolation and containment of the airstream, Ruskin Bubbletight industrial dampers for round and rectangular air paths will meet or exceed bubbletight leakage requirements in conformance with AMCA Standard 500-D Section 8. lbs. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). angles together at corners of dampers. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. ,Application The No. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Catalog. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Specifier Select Option Dampers shall be equipped with factory installed damper. Damper Width “A” Dimension in inches ()The CDRI95 Round Isolation Damper is designed for round duct work capable of 20" w. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. 2. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design.